Hildebrau April 07, 2014 for Model Number Haier BC112G Wine Cooler I have a Haier BC112G Wine Cooler with a bad PTC Relay. It has the part number: P6R8MC OR0506 stamped on it. It has a single male input pin on it and two female outputs to the compressor. I was able to open up the relay and lightly sand both surfaces of the disc inside and probably ended up rotating it slightly and put it back together and it then had continuity through it. Previously it did not. Now it works. However, i'd like to replace it, as it has some sections of one side of the disc that are ruined and won't provide continuity. Sadly, this part number can't seem to be located anywhere that I've seen. Lots of "P6R8MC" matches, but nothing specific to the OR0506 suffix. Is there a translation for what that part of the number decodes to? I assume it has the resistance built into the part number. I'd like to find a single pin replacement of identical resistance, if possible. The one listed here on APPro seems to have 3 pins.. Not sure which ONE of those I would use. Any guidance for me? Thanks!
1 Answer Hello! Unfortunately, the relay listed for your model has been discontinued and is now only available with the compressor, part number RF-1750-284. Thanks! Read More...
Jb March 20, 2014 for Model Number Haier Kegerator HBF205EBSS Looking for a PTC relay compatible with P6R8MD- OR0505. Also wondering what ohms this relay is? Compressor: LG MA53LBCM.
1 Answer Hello JB! Unfortunately, the manufacturer does not offer the relay separate from the compressor assembly for your model. The part number is RF-1750-49. Thanks. Read More...
Carlton February 25, 2014 for Model Number MCBR360S I have a small refrigarator that won't cool, it comes on then there is a click sound and it goes off, this will happen every 4 to 5 minutes.
1 Answer Hello Carlton. Here is a link to our Repair Forum, this is a free service to our customers. Use this link to access the repair for your question. http://forum.appliancepartspros.com/refrigerator-freezer-repair/193358-freezer-fridge-not-cooling.html Read More...
Richard December 18, 2013 for Model Number HVFM20ABB I need the overload protector on my Haier wine cooler. The part has two codes: P6R8MC and OR0402. Do you sell this part? Thanks
1 Answer Richard, Unfortunately it appears that the manufacturer has discontinued the overload relay RF-4800-34 with no replacement. Read More...
Peter L. November 22, 2013 for Model Number MCWC16MCG My small wine refrigerator by magic chef is running and cooling until the compressor gets so hot that the thermo protector clicks and shuts down the unit with no automatic restart. After turning off, cooling down and turning back on, the unit will start up, run and cool until the compressor again overheats. Could this be caused by the PTC Relay or is it the compressor?
1 Answer Peter, The compressor will only run based on the temperature in the unit. If the unit thermostat is not reading that the temp is cold enough it will keep the compressor running. The most likely cause would be a faulty thermostat WDF22.5A-L. Read More...
Justin September 16, 2013 for Model Number Haier HSP03WNAWW After reading the questions listed on your site it seems that i need to replace the starter relay and overload unit on my mini fridge. I am having the same problem as many people where my compressor gets realy hot but the fridge does not cool. I have removed the relay and upon inspection i noticed the small disk inside seems to have its coating missing from one side, where it makes contact with the terminals inside. I am assuming this is due to arcing or overheating causing it to burn away. It needs replacing either way. My problem comes from fining the right parts to replace them with. The number on the relay is P6R8MC OR0411. Any assistance would be extreemly appreciated.
1 Answer Hello Justin. Sorry, you must purchase the compressor on this model for the start device. It is not listed separately. You can try a 3 in 1 TJ90RCO810, but it is not the one made for the unit. Read More...
Dana666 September 09, 2013 for Model Number hsp03wnaww I have a Haier compact fridge that was working fine until I unplugged it. When I plugged it in again there was no power to it, seemingly, since it wouldn't come on at all. I typed in the model number on this site and it seems there is no record of this model! I thought maybe the problem was a starter and it has a p6r8mc small black plug in with ORO402 under that number. How can I troubleshoot this?
1 Answer Dana666, You will want to follow the power cord and check the end on the refrigerator to make sure that you are getting 120 vac. If there is 120 vac then check the compressor to make sure that there is 120 vac coming to the compressor if not then the thermostat is most likely the cause of failure and if there is power then the relay. Read More...
Tony August 19, 2013 for Model Number Vinotemp Model No. TC32G, Hi My Vinotemp Wine Cooler; Model No TC32G just stop getting cold (81F), I checked the lights, digital diplay and fan which works fine. Look at the power board (External) and no obvious blown components. The unit compressor gets hot to the touch and there seems to be a loud clicking sound every minute - as a relay reset. The compressor is a LG NS36LACG and the relay on the side of the compressor is a P6R8MC OR0509. What would I have to do to get the unit working??
1 Answer Tony, It sounds like the relay may be blown and you would need to replace the relay. Read More...
Jeff July 23, 2013 for Model Number fwc342gbo Should this have resistance? Electrolux wine cooler Contact has signs of thermal wear.
1 Answer Hello Jeff. From terminal to contact, it should read closed for continuity. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Garyg July 04, 2013 for Model Number vinotemp I got a free vinotemp wine fridge at a garage sale that wasn't working. It comes on for about 10 minutes and then shuts off. the compressor gets very hot during this time, especially the copper tube with a bulbus end that has a copper wire that leads to the thermostat. After the unit cools, it will start up only after turning the thermostat to "off". It makes a louder click than normal when turning it back on and I think this is some type of reset for a device that determines overheating(??) It will then work for a few minutes and then shut off again with the same hot compressor. The coils inside are getting cold and the condenser fan is working. Obviously not the starter relay since it is starting when cool. Any Ideas?
1 Answer Gary, Based on this information it sounds as though you may have a partial restriction in the sealed system in which the refrigerant will partially get through the filter dryer. This will back the system up and cause overheating of the compressor. Also if there is a condenser fan that is not operational then this would cause the issue as well. Read More...