Robert H April 21, 2022 for Model Number RFG297ABRS/XAA Thanks for identifying the correct Model of my refrigerator. Both refrigerator and freezer stopped cooling. The LED light on the Inverter PCB Board was not lit. Self diagnosis gave no codes. I put the refrigerator on Force Freeze mode. With this, the refrigerator began cooling and the LED light on the PCB board lit up, no blinking. If I take it off Force Freeze mode it will no longer cool. Does this sound like the Control Board needs to be replaced? When I compare my control board with the picture of the DA41-00538M on your site, there is an additional plug my board does not have. Will this be an issue? Thanks again for your help.
1 Answer Robert, while it is very likely that the main control DA41-00538M has failed, it would be recommended that the thermistors are tested for resistance to ensure that they are not the potential cause of failure. At room temperature (around 78°F), the thermistors should measure 4861 Ohms. The thermistors should then test 5225 Ohms at 75°F, 6281 Ohms at 66°F, 7032 Ohms at 60°F, and 8867 Ohms at 50°F (if cold water at this range is available to be used for testing the thermistors by placing the thermistors in the water). Read More...