Quintin January 12, 2021 for Model Number DV48H7400EW/A2 01 Hello, please forward any knowledge on this situation. Dryer is 5 years old and has worked perfectly until now. Symptoms- Dryer (on any settings) will start and run fine however no heat, BUT the unusual part is the following- the timer will countdown as usual for several minutes and then drops suddenly (example- "Normal" cycle starts at 42 minutes and counts down to 39 minutes, but then suddenly drops to 23 minutes. It continues on the countdown to 3 minutes but then suddenly jumps back up to 15 minutes). When I first began having the issue it would suddenly drop to 1 minute. I pulled the codes and scanned on the SmartCare app and was telling me the door was not closed. I ordered a door switch, replaced it, but no change. Now I don't get any codes at all. I have spoken with the folks at Samsung but they didn't have any diagnostic suggestions. I am fully capable of replacing the parts myself, but not sure of a solid "guess" on the issue. My thought was that since the timer is jumping around erratically, coupled with no heat, that it's probably the control board. However I don't want to start replacing parts until it's fixed- I can buy a brand new equivalent Samsung dryer at Home Depot right now for $698. The control board alone is $200. Many thanks in advance for your suggestions !!
1 Answer Quintin, the sensor bars would need to be checked to ensure they are clean. This can be done with vinegar and a course cleaning pad. Then, after checking to ensure there is proper voltage at the terminal block (240VAC when testing from the red wire to the black wire), the power cord would need to be unplugged from the outlet and the control thermistor DC32-00007A would need to be tested for resistance from the main control DC92-01626A. At the connection CN4, the red wire and the blue wire would be tested together for a resistance of 10KO at room temperature if the thermistor is operating properly. If the thermistor reads properly, the sensor bars are clean, and there was 240VAC then the most likely failure would be the main control based on the information provided. Read More...
Kevin July 28, 2020 for Model Number DV48H7400EW/A2-0000 my dryer will keep running until unplugged. lights all come on the control panel but no warnings.
1 Answer Hello Kevin,the motor run relay is stuck closed, it is part of the main control board part DC92-01626A. Read More...
Essex July 14, 2020 for Model Number DV328AEW/XAA mydryer is a Samsung front load model #DV328AEW/XAA The Power button will not turn on the dryer but whwn you turn the selector knob to a function the dryer will come on and wok in that function and you have to push the start/pause button to let it stop. what could be the problem how can I fix that
1 Answer Essex,Based on the information provided it sound as if the user interface is the issue, Unfortunately, the manufacturer has discontinued this part and has not made a replacement available. Read More...
Clif April 18, 2018 for Model Number DV48J7770EP/A2 Unit will power up, but will not run any cycle. Filter check light blinks six times, that is all it will do.
1 Answer Clif, You will want to check to make sure that the filter is clean and check to make sure that the vent is clear. If this all checks ok then the issue will most likely be caused by a faulty main control board. Read More...
Todd G March 25, 2017 for Model Number dv48h7400ew/a2 I posted on the repair forum a week ago but I haven't seen a response yet. The elements won't heat but motor will run. I have ohmed out the thermal fuse, thermostat and blower limit. When I ohmed the thermister it read 10,500 olms @ 71 degrees, I compared it to a 10,000 ohm thermister I have on my service van and they were very close. Is the thermister a 10,000 ohm? I pulled the wires from the on-board heat relay and jumpered them, it heats fine. So that eliminates a faulty thermostat or heat limit. After checking all this I ordered the main control board and that didn't fix it. I'm needing some direction here, can you help. thanks Todd
1 Answer Todd, The thermistor does sound like it would be good and is not what is causing the unit to not heat. This issue would most likely be a faulty centrifugal switch on the motor with the heater and all thermostats being good. To be sure here is a way to check it. There are 2 components other than the thermostats which would cause the heating element not to work. First is the motor and second the Control board. The best option is to disconnect the power to the unit and access the heating element. Disconnect one wire that is going to the heating element, preferably the one on the thermostat side. Plug the unit back up and using a multimeter you will want to turn the dryer on and test for 120 vac at the terminal on the heater where the wire was disconnected. What this will do is eliminate the heater element itself and the motor. If there is 120 vac at this point then you know the heater is good and the motor is good because the other 120 vac coming through the thermostats is the control board side of the circuit. If there is not 120 vac at that point then you will want to test the other terminal on the heater and check for 120 vac. If there is not 120 vac then the motor would be bad . Read More...
Jeff November 22, 2016 for Model Number DV48H7400EW/A2 My dryer currently is not powering on. There is voltage coming from the wall. We recently had condensation appearing on the display from a backed up duct (damn bird nest). Would this condensation have ruined the dryer user interface assembly? Nothing on the display is working.
1 Answer Jeff, It is certainly possible that the display board or the main board of the unit was affected by the moisture from the duct being blocked up. Read More...
Jamie P September 24, 2016 for Model Number dv48j7770ep/a2 This unit will run for a few loads then the display goes blank and the unit won't power up for a day or so then does. The electric an d breaker are 240 and the neutral is good. There is not diagram but the board has 120vac present when it is blank. Does it sound like the UI or the main board or both?
1 Answer Jamie, This issue sounds like it would be caused by a faulty main control board which is part number DC92-01729A. Read More...