Lilo November 17, 2016 for Model Number RS2630SH How does the thermostat defrost heater wiring hook up and to what wires they were missing.
1 Answer Lilo, The defrost thermostat on this unit would just connect to the connector on the wall of the unit. Read More...
Elvis June 27, 2014 for Model Number Samsng, Model# RS2630SH Refrigerator stopped cooling, check the back condenser fan motor burnt. Ordered complete assembly and fan from you guys and got it today. Installed the fan and plug in refrigerator Fan started, compressor running (cleaned the condenser too), freezer not blowing cold air. Removed panel to look inside evaporator fan verified running and evaporator coil is just slightly cold. Now what......please help, don't to spend money for new one..
1 Answer Elvis, If the unit had not been running for a period of time then you will want to give it time to get down to temp. Recommended 24 hrs. If the unit had been running then it sounds like either the compressor is not running or there is a sealed system issue which would need to be checked. Read More...
Larry March 08, 2012 for Model Number samsun rs2630sh I replaced the temp sensor on my freezer, it worked for 2 months then will not freeze now. Should I replace the thermostat sensor too? This refg is not that old.....
1 Answer Hi Larry. You will need to open the freezer door to see if the fan is operating. If not then I recommend that you disassemble the back cover and see if the connection to the fan is OK. Use a volt/ohm meter to check the wires going to the fan and make sure that under normal run time the fan is getting the 120 vac from the main control board. If not check the main board connections and make sure they aer clean and tight as well. if you are not getting the 120 vac from the board, it is part # DA41-00219C. Static ground yourself to bare metal frame a few times to get rid of the static so you do not induce it into the new board and touch the new one by the corners only. If the fan is not running and the back wall is not frozen, use the replacement kit part # DA97-01948A. If it is, then you will also need the outer cover w/ inner Styrofoam and seals that will break when removed. It comes with a sensor kit as well. Are the condenser coils clean? Use a condenser coil brush and a shop vac to clean them, this will start a no-cool as well as the cond. fan not running as well. Condenser coil brush part # TJ103. Make sure all door seals are sealing properly as well as the lights shutting off when the doors are shut. Thank You. Read More...