Glenn April 05, 2020 for Model Number KDRP467 KSS07 I had a no power to the display and the oven would not turn on. Checked the Oven Shutdown Fuse and it was ok. I checked the Control Thermal Fuse and it was blown. I replaced it and the oven is working but Console Blower does not turn on. I disconnected the grey and white wires and checked the blower and got 14.7 ohms across the terminals but the unit still would not turn on. What voltage and current does the blower motor need to see from the grey and white wires to turn on? I want to check and see if it is getting it?
1 Answer Glenn,You will be looking for 120VAC. If no voltage found then the control board would need to be replaced. Read More...
Sandy February 25, 2012 for Model Number kdrt467kss09 how do u take out the blower motor to install anew one.
1 Answer Sandy, You'll need to move the range away from the wall, You may need some help, it's a heavy unit. Here you go: "1. Turn off gas supply and disconnect power to the range. 2. Pull the range out of its mounting location so that you can access the rear of the unit. 3. Remove the top and center braces and the rear panel for the blower motor assembly that you are servicing. 4 Remove the four screws from the blower motor assembly cover and remove the cover from the range.5. Remove the four mounting screws and the air vent screw from the blower motor assembly and remove the assembly from the range." Thanks and Good Luck Read More...