Nate September 08, 2020 for Model Number RJRS4270A Issue with the freezer staying cold. Running in Diagnostic Control Mode, found two tests that have issues: Service Test 08 Freezer/EVAP Fan Result: Lo - FAN TOO SLOW Service Test 10 DAMPER CLOSE Result: Visually inspecting, it does not close. Service Test 9 DAMPER OPEN passes. If I manually close the damper, then run the test, it opens. Replacing the DAMPER and Fan didn't solve the issue. Thinking a board issue, maybe? Thoughts? Thanks!
1 Answer Hello Nate,the main control board WP67006854 controls the operation of both of those parts. If the parts are still not operating correctly after being replaced the next step is the mainboard replacement. Read More...
Gj December 27, 2018 for Model Number RJRS4270D I have a 10-12 year old Jade 42" fridge. Model # RJRS4270D. The fridge is powering off on an irregular schedule. No lights, no cooling, etc. Usually off for an hour or two and then powers back up. Food stays frozen but fridge warms up to low 40's before the fridge powers back on. Repair guy not familiar with the brand and says all he can do is replace all three controller boards, and then with no guarantee. Any ideas on whether or not this problem can be isolated to a single board or some other problem?
1 Answer GJ, We can isolate the problems to two components of the control assembly inside the upper compartment. The most likely issue would be the WP67006854 Board, Main Display, after all these years there may be a weak solder joint or a weak silver tracer on the board that eventually fails and opens, then closes and the refrigerator will operate until the weak joint opens again. The next possibility is the WP67001360 Transformer / Power Supply Board. It "transforms" the 120 VAC from the power cord into 12 VDC and 26 VDC into the main display board. If the "windings' in the transformer are weak or fail, you'll loose the low voltage supply to the main board.and it will go "dead", but it is the less likely failure of the two. Read More...
Albert December 11, 2018 for Model Number RJRS4280D I have a Jade RJRS4280D refrigerator. It seems to keep the refrigerator side cold as it is set, but the freezer is set to 0 and it fluctuates between 0 and 29, usually in the high teens or low 20s. It's very sporadic behavior, but usually, the freezer is too warm to house ice cream.
1 Answer Hello Albert, The freezer side not maintaining proper temperatures usually indicates an issue in the sealed system. This would be a situation where a Freon certified tech should connect to the high and low sides to verify proper operating pressures for proper diagnosis. Read More...
Scott July 24, 2017 for Model Number RJRS4270A I have a Jade 42" refrigerator model RJRS4270A. Jade was purchased by Jenn-Air then Whirlpool. I had a power surge a couple nights ago and in the morning the refrigerator did not operate. There are no lights, compressor doesn't run, no display panel etc. - completely dead. I have power at the outlet and to the on/off switch. I have 110 to the compressor board and power supply module. I "think" (tested lead out of the power supply but can't remember results) I have power to the main control board from the power supply module. I am curious of professional opinions on if it is more likely a main board or the power supply module? What readings should I get from the power supply to the main control board? Anything else I should check? The main board is part Whirlpool # WP67006854.
1 Answer Scott, With nothing working on the unit this will most likely be the main control board that is faulty and would need replaced. Read More...
Jack September 21, 2015 for Model Number RJRS4270D I have a Jade RJRS4270D refrigerator. It seems to keep cold fine, but the door lights and display panel no longer turns on. When I turn off the main power and turn it back on, the light would turn on again but then it stays on after the door is closed, and the display gets stuck and doesn't respond to input. It's very sporadic behavior. I think the main display board needs to be replaced (part AP4081099). Are there any pre-cautions I need to be aware of? Such as turning off main circuit-breaker? I want to make sure I don't make the situation worse.
1 Answer Hello Jack. Based on the information you provided, you will need to order and replace the main display board WP67006854 on the unit. Read More...