Ed July 03, 2017 for Model Number MCG8000AWW Dryer code DD showed last week now showing code DC on lower cabinet. can use on in timed drying. HELP!
1 Answer Ed, The DD would indicate that the unit is being put into diagnostics which would also be what the DC stands for. If the unit is doing this on its own then this would most likely be a control board issue. The part number for the control board is WP31001562. Read More...
Don June 21, 2016 for Model Number Whirlpool 31001660 This the membrane for a Maytag Neptune dryer which has the clothes dryer on the bottom with the "dry cleaner" on top. I have searched for a replacement for the membrane #31001660 so I can use both the dryer and the "dry cleaner". I cannot find the part since all distributors say it is no longer available. Any suggestions?
1 Answer Sorry don, 31001660 has been permanently discontinued by the manufacturer and we don't know of any source or replacement for the part. Read More...
Bill April 25, 2016 for Model Number mcg8000aww maytag neptune drying center When drying clothes the dryer stops part way through the cycle and (HP) comes up in the window (a temperature sensor problem has been detected) I shut off the dryer and turn it back on, and it will run for about 5 or so then it stops again and shows HP in the window again. What causes this problem. could it be the Moisture Sensor?
1 Answer Bill, The most likely cause for a temperature sensor problem being detected would be a faulty temp control thermistor WP31001590. Read More...
Chaz February 19, 2016 for Model Number MCG8000AWQ The upper cabinet is fine. When I start the lower dryer all is good for a few minutes to a few seconds, then the erratic beeping starts and the dryer switches to Air/fluff dry. Trying to run the diagnostic mode is useless as it keeps canceling itself. Knowing that there is no more availability for the control panel, i did the manual membrane test with an ohm meter and there are no stuck buttons (all read open, unless depressed). Logic Board, or is there another suspicious part to the control panel?
1 Answer Hello Chaz. Yes, based on the information you provided, it sounds like the logic board is bad on the unit. Read More...
Joesyoyo October 16, 2015 What is the red letter "Replace" thingy on lower dryer drum of may tag neptune drying center, and how often does it need to be replaced?
1 Answer Joesyoyo, If there is a red letter REPLACE on the dryer drum then this is a bounce dryer stick and would be replaced when it says to replace if you are able to locate them. This is not a part that would come on the dryer. Read More...
Melanie August 18, 2015 for Model Number MCG8000AWW My lower dryer heats, but it stops after a few minutes. Sometimes I can turn it back on immediately. Sometimes I have to wait several minutes.
1 Answer Hello Melanie. If the board stays on, but the drum stops turning, you will need to check and see if the motor is bad and is overheating in the unit. You will also want to check and see if the relay board WP53-4643 is bad in the unit as well. Read More...
T.R. May 17, 2015 for Model Number MCE8000AYW The upper cabinet works. Lower dryer starts but shuts off in about 15 to 20 seconds. The off button does not work. Does this unit need a new control board?
1 Answer Hello T.R., You should check for the following: • Lint buildup around drive motor. • Low voltage present. • Blower impeller blocked in blower housing. • Drive motor - start switch contacts stuck closed. Read More...
Mark D April 20, 2015 for Model Number MCE8000AYW I have replaced the thermal fuse, motor, control board, and relay board and the console. The dryer will not start. There is a click when start button is pushed the first time and a odd sound the second time when the display goes to pause. This symptom is unchanged no matter what part has changed. I also replaced the thermistor on the lower dryer side. The upper dryer operates normally. I have been unable to perform the console test on the new console. It does not go into diag mode ....I got it in once but can not get it back. The original console did go into diag mode but the lights did not go out in the expected order. I got a recommendation to change the console. Thank you
1 Answer Mark, You will want to make sure that the console has a good firm connection but it is sounding like the logic board in the unit is faulty with the issue that you are having. Read More...
Mark D April 08, 2015 for Model Number MCE8000AYW I have replaced the motor, relay board and control board. Lower dryer will not start. Upper dry operates normally. This is the original symptom. Diag code is 8 which is a stuck key. Membrane test seems ok. I push all buttons and the lights go out but on an odd order...Membrane is not available any more so I can't try that. Any ideas?
1 Answer Mark, With the membrane switch test the buttons that you are not selecting going off would be caused by faulty console. As for the unit not starting, you would want to check the thermal fuse and door switch but it sounds like the console is the issue. Read More...
Bruce January 18, 2015 for Model Number MCE8000AYW Both the upper and lower cabinet do not respond to changes when pressing the keypads...I also cannot enter diagnostic mode as the lower unit shows 18 minutes and the upper also has a time display. I can run the lower unit, but only in sensor dry mode..not time mode. Is this the membrane unit which is bad?
1 Answer Bruce, This issue would most likely be caused by a faulty logic board which is part number WP31001562. Read More...