Linda July 31, 2014 for Model Number JDB2100AWB I have a Jenn-Air Dishwasher that I am unable to start. The touch pad only lights up when I press normal wash, heated dry and sanitize. Is this a Control Panel problem or a Control board problem. I had been having problems with the lights for the past few months, the dishwasher seemed to be runnimg just fine when I could get it to start. Thanks
1 Answer Hello Linda. Based on the information you provided, the control panel 6-919766 is bad and will need to be replaced on the unit. Read More...
Fronesis November 04, 2012 for Model Number Jenn-Air JDB 2100AWS I have just ordered a replacement touch pad, Part #6-919766. I am looking for specific instructions on how to install it. Can someone please give me some guidance? Thanks.
1 Answer Hello Fronesis. 1. Disconnect power to the machine. 2. Remove the Inner Door Panel. (See paragraph Inner Door Panel removal). 3. Remove PC Board Housing Cover. (See paragraph PC Board removal). 4. Disconnect Membrane Switch from PC Board. 5. Remove PC Board Base. 6. Lift out Latch Assembly. 7. Remove 4 screws securing Control Panel to Outer Door. Read More...
John May 24, 2012 for Model Number Jenn-Air Dishwasher JDB2100AWS Dishwasher works in quick wash only. Control Panel lights up quick wash, heated dry and start/cycle indicator lights when start/cycle is selected. Able to cycle through delay numbers as well. All other modes will not select. What can I do to verify it is the control panel at fault?
1 Answer Hello John. Remove the ribbon cable and make sure it is clean, dry, and seated properly. If so, replace the control panel 6-919766. Read More...
Bruce C. October 29, 2011 for Model Number JDB2100AWS Jenn Air dishwasher. The only way to get the touch pad to light up is to hit the delay button. When you hit the delay button the lights turn on for the variuos functions, except the start cancel button doesn't light or work. After a short period of time the lights go out again. Any recommendations on which part I may need?
1 Answer Hello Bruce. Based on the information you provided, it sounds like the control panel 6-919766 is bad and will need to be replaced. Check and make sure the ribbon cable is clean and dry and is installed properly in the control board. If so, and the problem continues, you will need to replace the control panel. Hope this helps. Read More...