Eli January 19, 2022 for Model Number Bosch Benchmark Series 36" Stainless Steel Gas Cooktop - NGMP656UC Hi, Can this Re-Igniter be used to replace my defective one? Thanks
Court September 04, 2020 for Model Number JGC9536ADB I replaced the burner assembly on large burner.The igniter keeps clicking, unplugged this burner another burner igniter started clicking, do I need to replace blue box-spark module?
1 Answer Court, based on the information provided, it does sound like the spark module WP8286828 has failed. It would be recommended that the wires are checked for any bare or loose spots, and if there are none, the module would be the most likely issue. Read More...
Bruce June 03, 2020 for Model Number KFGS366VSS02 I woke up one morning to find the ignitors, all 5, firing on their own. Disconnected the 5 knob switch harness and they kept firing. Any combination of hooked up ignitor leads would fire those ignitors connected. Disconnecting all 5 revealed a faint clicking sound coming apparently from the HiV end of the ignitor control module (a blue box). I opened it and there is no sign of arcing on the LoV end (the HiV end is encased in epoxy). I assume that has failed?? I ordered one yesterday.
1 Answer Bruce, based on the information provided, the spark module WP8286828 has failed and would need to be replaced. Read More...
Tim S May 07, 2017 for Model Number JGC8536BDS11 When I turn on the large, center burner, the ignitors continue to spark. I replaced the ignitor and the switch, but the problem continues. Is the spark module bad?
1 Answer Tim, First check the burner cap, base and burner area, they have to be clean and corrosion free. Make sure, once the burner flame has ignited and stabilized, make sure the burner flame is in contact or within 1/32 in. of the igniter cap. If all's OK, replace the spark module. This is a "re ignition" module, and has to be wired properly or it will continue to have ignition issues, Read More...
John September 01, 2013 All switches are off yet one burner sparks intermittenly....once every 10 minutes or so. The spark module (P/N" AP4358277) was replaced 10 months ago and has worked well up till now.
1 Answer John, You will want to check the continuity of the burner switches when they are in the off position. If any one of them have continuity then the part is bad and would need to be replaced. Read More...
Yonel June 15, 2012 All the igniters continue to spack after one burner is on. It's an intermittent problem. What can be the cause?
1 Answer Yonel, Since this is an intermittent problem, check and make sure you have a polarized, grounded 120 VAC outlet that the power cord is plugged into. It's most likely an issue with the spark module, like you guessed, but, it could also be a faulty igniter switch on the burner gas valve. Good Luck Read More...
1 Answer Hello Ali. Check and make sure all the burners are clean and dry and there is a good clean surface for the igniter to ground when lit. If so, you will need to replace the spark module WP8286828 in the unit. Read More...
Daryl M September 29, 2011 for Model Number jgc8536ads Is there anyway in which I can test the spark panel myself to make sure it is not working before purchasing a new one?
1 Answer Daryl, Not really, You can check for 120 VAC into the module. Then check for 120 VAC from each individual burner switch. But you cannot check for the 2000 to 2500 VDC out to the igniters. Thanks and Good Luck Read More...