Deepcoveoven for Model Number KEBS177SBL00

Our wall oven recently has been difficult to start. Pressing most of the buttons on the control panel work as expected - eg. pressing "bake", "convect", "easy convect", "self clean", etc.. all work fine to pull up the appropriate programming on the display. Pressing "On" however does nothing. In addition, pressing some buttons results in unexpected responses. Pressing "Oven Light" results in a Convect/Roast program coming up. Pressing "7" turns the oven light on. Pressing "7" again turns the oven light off. Pressing the "On" buttons does nothing or seems to send a 1 or 7 digit to the display. Would you recommend replacing AP6019275/WPW10312207 or do you think touch panel (item 4) on the expanded diagram for this model) is likely the culprit? Thank you!

1 Answer

DeepCoveOven, based on the information provided, the control panel WP8303879 would be the cause of failure. Unfortunately, this part has been discontinued by the manufacturer and is no longer available.

Read More...

1 Answer

George, Thanks for the question!!! The issue is being caused by a relay on the appliance manager sticking. The appliance manager is WPW10119143 and needs to be replaced.

Read More...

1 Answer

Joan, the oven sensor WPW10131825 would need to be tested for resistance. If it measures close to 1080 Ohms (between 1070 to 1100 at 77°F to 89°F) at room temperature, it is good and the most likely failure would be the relay control WPW10119143.

Read More...

1 Answer

John, the bake element WPW10207398 would need to be tested for resistance and it should measure between 26 to 30 Ohms. If it tests good, the most likely failure would be the oven relay control WPW10119143.

Read More...

1 Answer

Suzanne,

If you measure the size of your oven example if it is a 27" wall oven then this will be the cavity size.

Read More...

1 Answer

Billy, If the oven temp. is high, low or erratic, and there are no error codes in the display, the more common problem is usually an oven temperature sensor WPW10131825 has lost it's calibration and isn't supplying the proper circuitry to the control. There are no instructions that come with the part, but there is a video attached to the parts diagram that should be helpful. Thanks,

Read More...

1 Answer

Judy, to program cavity size, disconnect power to oven, wait at least 10 seconds, reconnect power, enter diagnostic mode by pressing OFF, OFF, START. Press key #6 to show cavity size select screen. To edit, press CLOCK key. Scroll through cavity sizes by pressing key #6 until required size is displayed. Once correct size is displayed, press the START key to accept modification.

Read More...

1 Answer

Hello Sharon. The code means. Replace oven user
interface 1. Unplug oven or disconnect power.
2. Replace the user interface WPW10312207.
3. Replace all parts and panels before operating.
4. Plug in oven or reconnect power.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google