Yjlee October 18, 2015 Hi I own a Jenn-Air stove and we're experiencing constant ignition problem. Also even when the stove is turned off, we could feel the electricity around the countertop. It's not strong but we have some cleaning problem. One of the technitians said replacing the spark module might solve the problem. We're not sure how trustworthy his comment is. Please share any thoughts. Greatly appreciate it. Thank you.
1 Answer YJ, The more worrisome issue is the "we could feel the electricity around the countertop" this could indicate a shorted or pinched wire in the harness shorting to the chassis or possibly reverse polarity at the power supply causing a "hot" neutral or ground circuit in the stove. You'll need to have that taken care of for safety reasons. The spark module could have an issue as well, especially a "reignition" module. It has to properly installed and wired to the individual burners correctly, but the power problem could be the cause of both issues, the range needs to have a properly polarized and grounded 120 VAC 60 Hz. power supply. Read More...
Harry H. September 22, 2014 for Model Number Jennair I'm replacing the spark igniter. The original wasn't available to the replacement part W10475147 was sent. I had some problems taking off the cover and two of the 4 wires came off before I could note where they were. They are black, blue, yellow and red. On the old part the wires are staggered in an up and down pattern where it looks like S1 and S3 are on one level and S2 and S4 are on another. On the new part, connectors are at positions 2,3,4 and 5, and are all in a row with positions 1 and 6 blanks. What colors go where on the new part. I think S1=P2=black, S2=P3=blue, S3=P4=yellow, and S4=P5=red. But I'm not sure. Are you? Thanks!
1 Answer Hello Harry, If you could please post the model number from the units' I.D. tag, we will be able to pull the wiring diagram for your unit and give you a good answer. Thank you for your patience and understanding in this matter. Read More...
John March 13, 2014 for Model Number Jennairjgs8869bdp Constant ignition sparking when any burner is turned on.
1 Answer Hello John. You need to check for a bad spark switches WP74011648 and WP74011647 on the unit. Also, make sure all the burners are good and clean. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Greg October 17, 2012 for Model Number Jds8850aas I replaced the spark module and the igniter switches at the gas control valve, but the right front burner continues to ignite when there is a flame present.
1 Answer Hello Greg, If you can light the burner with a match with the gas valve off, the gas valve is bad and must be replaced. You should turn the gas off to the unit until the repair has been completed for your safetys' sake. You need to order 12002342 for the right front burner and replace the valve before turning the gas back on to the unit. Check for leaks with lightly soaped water, (one teaspoon liquid soap to a quart of water). If this mixture is mixed with too much soap, the thickness of the soap will stop the leak since the gas pressure is so low. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. Read More...