Isagani July 26, 2012 for Model Number Maytag PDB2430AWX I want to replace the Spray Arm Support (AP4293905). How can I disconnect it from the PumP Volut (AP4364365)?
1 Answer Isagani, You will need to remove(unscrews counterclockwise) the center nozzle and tower WPY912899 WPY912912 and lift the lower spray arm from the support WP6-904026 then loosen and remove the pump cover/filter screws 903486 and lift the cover off the pump housing. unscrew the spray arm support nut WPY912930 and lift the support assembly up and off the cenetr shaft WPY912900 be careful, and don't loose the support seal ring Y912904 located on the top of the volute, or inside the bottom of the support arm. Read More...