Fred July 21, 2020 for Model Number JGC9536BDB16 Hi , Smoke came out fron the space under the right front knob, what could be the cause? spark ignition switch of the spark module? Thank you so much.
1 Answer Fred, With smoke coming from under the right front knob this would most likely be the ignition switch that has failed. Read More...
Jim September 30, 2014 for Model Number JGC9536ADS We have a Jenn-Air gas cooktop that has all 5 burners trying to lite, sparking, constantly even when all the burner knobs are turned off. I have tested all the valve switches and they appear to be all open when the valve is turned off. I even disconnected one of the wires from each valve switch and all the burners still continue to spark. What do you suggest.
1 Answer Hello Jim, While this is normally caused by a shorted burner switch or burner switch harness, it can sometimes be caused by the spark module WP8286828. Read More...
Jim September 29, 2014 for Model Number JGC8536ADS I have a Jenn-Air cooktop model JGC8536ADS. With all the burners turned off I can hear igniter sparking constantly. It is the left front burner that is trying to ignite. With valves turned off there is no gas to ignite,
1 Answer Jim, The most likely cause for the issue would be the igniter switch. You will want to do a continuity test on the switch to see if there is continuity in the off position. If there is continuity then the switch would need to be replaced. The part number for the switch is WP74007753. Read More...
Kevin February 14, 2013 for Model Number JGC9430ADS Gas is leaking out through burners when switched off. What parts should be replaced?
1 Answer Hello Kevin. Based on the information you provided, you will need to order and replace the manifold WP7513P305-60 on the unit. Read More...
Jack F. May 04, 2011 for Model Number JGC8430BDS Burner 4 will not catch fire. There seems to be no spark. The gas comes in. Also the spark part in Burner 1 has a small crack and it fires when any of the other burners are turned on. How can I fix it? Thanks.
1 Answer Hello Jack! When you turn one burner on, all burners will spark. For the one that is not lighting you will need to inspect the area where the gas will come into contact with the ignitor and make sure it is clear of any debris. Make sure the ignitor WP74009336 has not cracked. It is also possible that the spark module WPW10475147 is becoming weak and may need to be replaced. Hope this information helps. Read More...