Duaine October 19, 2020 for Model Number 11082873110 Our cold water will empty at full pressure for a period of time, then it will barely enter the washer. This does this sporadically on different washer settings. I checked the hose and the filter screen. Both are open. What could be the problem and which part would fix it please. Thank you. Duaine
1 Answer Duaine, it would be recommended that the water valve 285805 is tested for 120VAC when the water flow from the cold water solenoid decreases. If there is 120VAC, the solenoid is weakened and the valve would need to be replaced. Read More...
1 Answer Ken,For a proper diagnosis, we would need you to please verify the model number from the units' I.D. tag since it will not come up for us as a valid model number. Read More...
Tony February 25, 2017 for Model Number WTW4850XQ0 Only delivers cold water on all settings, is it temp switch problem or water inlet valve.
1 Answer Tony, You will want to test the thermistor on the unit and make sure that it is good. The thermistor should read at 77 degrees between 49K and 51K ohms of resistance. If this checks ok then the main control board would be the most likely cause for the issue. Read More...