Questions & Answers

For Whirlpool Refrigerator Defrost Timer (Part Number: OEM17955633)

1 Answer

You were pretty close to the correct wiring of the new timer. Based on the wiring diagram for the model number you supplied, the black timer motor wire should have been placed on terminal 1, the orange wire should have been attached to the no.1 terminal as well. The pink wire attached to the no.2 terminal. The white wire attaches to terminal no.3, and the red wire to terminal no.4. This will provide a defrost cycle every 8 hours of compressor run time, after the defrost bimetal(thermostat) closes. It may seem like it's a long period of time between defrost cycles, but that is determined by door openings and usage and loading of the compartments. Once you have it wired correctly and have double checked and made sure the evaporator coils are all clear of any ice or frost, allow the refrigerator to run and cycle a few days before yopu recheck for ice on the back wall or vents.

Read More...

1 Answer

Hello Micah,
You will need to connect the loose jumper lead to terminal number one (1) on the new defrost timer.

Read More...

1 Answer

Hello Oscar,
Attaching the loose lead to terminal number one (1) will result in a continuous defrost configuration, (ideal for your application).

Read More...
Emery S. for Model Number EET201MMNR2

This Refrigerator is 37 years old, First break down. Unit frosted up in freezer. I had the Timer replaced but that didn't help. The heat strip has 120 volts on both sides. It does not get hot with the 120 volts getting to it. I checked the Defrost and there is no continuity between the two wires coming out. I think this is a bad one. Since I can't find my model number because of it's 37 years old, what can I replace it with? Will the p/n-2321799 work? Can you help me? Thanks

1 Answer

Hello Emery,
WR50X60 is a 60/40 configuration so it should work. If the unit runs a bit cold, you may need to go to a colder one like the 58/30 WR50X10025. The numbers I am listing is the high temperature where the thermostat will open and the low temperature where the thermostat closes. (i.e. opens at 60°F and closes at 40°F).

Read More...

1 Answer

Fuzzyragdoll,

To remove the clips on the post you will just need to slowly work the metal clip up. There is really no easy way to do this.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google