Won't start is the most common symptom for General Electric DPSE592EA2AA. The instructions below from DIYers like you make the repair simple and easy. Many parts also have a video showing step-by-step how to fix the "Won't start" problem for General Electric DPSE592EA2AA. So, if your DPSE592EA2AA dryer does not start when the door is closed, not starting or won't turn on, the following info will help you identify the problem.
Parts for General Electric DPSE592EA2AA
The Interlock Switch is an OEM replacement part for GE electric and gas dryers. This safety component monitors the door closure, preventing operation if the door is not securely closed and latched. The switch measures 2 inches long and 1/2 inch wide.
Symptoms of a faulty interlock switch include:
Causes relate to the internal component contacting the door frame over 50,000 open/close cycles potentially exposing wiring to wear. Regular cleaning the external switch area prevents dust or lint buildup skewing performance.
This genuine GE switch is compatible with Hotpoint and RCA dryers as well.
Note: Can be used as a dishwasher door switch on specific models. Check your model number for the most accurate results.
Order now and we'll ship it out Today
Over 94% of our orders are delivered in 2 days or less
The Door Switch is an OEM part for GE dryers, designed to ensure the dryer does not operate when the door is open. This safety feature is crucial for preventing accidents and ensuring the appliance operates efficiently and safely. The switch signals the dryer's control system about the status of the door—if it's open or closed—thereby allowing or preventing the start of a drying cycle.
Causes of damage to the door switch often include mechanical wear from repeated use, accidental damage from loading or unloading, or electrical issues such as short circuits.
Symptoms of a bad Door Switch include:
This OEM GE part is also compatible with Hotpoint, RCA, and some Kenmore models.
This dryer motor kit powers the drum and blower. Replacing a weak or failed motor restores proper tumbling and airflow so the dryer starts reliably and dries loads more evenly.
The Door Latch is an OEM part for GE dryers. This part ensures the dryer door stays securely closed during operation, activating the safety switch to allow the dryer to operate. The latch mechanism engages with the door strike to lock the door, preventing it from opening while the dryer is running, which is essential for both safety and proper functioning of the appliance.
Causes for replacement can include normal wear and tear, accidental damage, or a misalignment that prevents the door from securely latching.
Symptoms of a bad Door Latch include:
The Door Strike is an OEM part for GE dryers. This component is crucial for ensuring that the dryer door latches properly when closed. It interacts with the door catch mechanism to secure the door during operation, preventing it from opening unexpectedly, which ensures the dryer operates safely and efficiently.
Symptoms of a failing Door Strike include:
Causes of a bad door strike can include wear and tear from regular use, physical damage from slamming the door or mishandling, and misalignment caused by repeated opening and closing.
This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models.
Note: If the door catch is also needed, use part number WE1M1011.
The Power Terminal Block is an OEM part for GE dryers. This component serves as the connection point for the dryer's power cord, distributing electrical power to the various internal components of the dryer. It ensures that the dryer receives the proper electrical supply needed for its operation.
Causes of a bad power terminal block can include electrical overloads, corrosion from moisture exposure, and loose or frayed wiring connections. These issues can lead to improper power distribution or complete loss of power to the dryer.
Symptoms of a bad power terminal block include: