Roper Microwave producing a burning smell: Common Causes & How to Fix

1 Roper Microwave Waveguide Cover

Most Common Solution
Repair Instructions:

If you notice damage, arcing, or burning on the waveguide cover of your Roper microwave, it's a sign that something isn't right. In such situations, or if the cover won't stay in its proper position, the best course of action is to replace it with a new one. The waveguide cover is essential because it protects the inside of the Roper microwave and ensures that it functions safely and effectively. When it's damaged or out of place, it can lead to problems like arcing (sparks) and burning, which are not only concerning but can also damage your Roper microwave further. By replacing the waveguide cover with a new, undamaged one, you can maintain the safety and proper functioning of your Roper microwave. This simple replacement ensures that your Roper microwave works as it should, without any unusual issues.

How to Replace Roper Microwave Waveguide Cover

  1. Safety First

    • Prioritize your safety by disconnecting the Roper microwave from the power source. Unplug it from the wall outlet or switch off the dedicated circuit breaker.
  2. Locate the Waveguide Cover

    • Identify the waveguide cover inside the Roper microwave. It is typically a rectangular or square-shaped panel made of metal or mica.
    • Refer to the Roper microwave's user manual or search for diagrams online to help you locate the waveguide cover.
  3. Order the Correct Replacement Cover

    • Determine the specific model and type of waveguide cover required for your Roper microwave. Check the user manual or contact the manufacturer to obtain the correct replacement part information.
    • Purchase the replacement waveguide cover from authorized dealers, appliance stores, or online retailers.
  4. Prepare the Workspace

    • Clear a clean and spacious area to work on the replacement. Place a soft cloth or towel on the surface to protect the Roper microwave from scratches.
  5. Access the Waveguide Cover

    • Depending on the Roper microwave model, you may need to remove the Roper microwave's internal cover or access panel to gain access to the waveguide cover.
    • Follow the instructions in the Roper microwave's user manual or search online for specific disassembly steps for your model.
  6. Remove the Old Waveguide Cover

    • Carefully remove any screws or clips holding the old waveguide cover in place.
    • Gently detach the old cover, taking care not to damage the waveguide or other internal components.
  7. Clean the Waveguide Area

    • Before installing the new waveguide cover, clean the waveguide area using a soft, lint-free cloth.
    • Remove any grease, food particles, or debris that may have accumulated.
  8. Install the New Waveguide Cover

    • Position the new waveguide cover in place, aligning it accurately with the waveguide opening.
    • Secure the new cover using appropriate screws or clips, ensuring it is firmly in place.
  9. Reassemble the Roper Microwave

    • Follow the reverse order of the disassembly steps to reassemble the Roper microwave.
    • Ensure all panels and covers are properly aligned and fastened according to the manufacturer's instructions.
  10. Reconnect the Power

    • Plug the Roper microwave back into the power source or switch on the dedicated circuit breaker.
    • Ensure the Roper microwave is receiving power.
  11. Test the Replacement

    • Close the Roper microwave door and turn it on.
    • Run a short Roper microwave test to verify that the new waveguide cover is functioning properly and there are no unusual sparks or arcing.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Waveguide Cover parts

2 Roper Microwave Power Supply Board

Most Common Solution
Repair Instructions:

Once you've made sure that your Roper microwave is clean from any leftover food bits and the waveguide cover is undamaged, but you still detect a burning smell, it's possible that the power supply board is the culprit. To check, take a look at the power supply board for any signs of burn marks or damaged components. If you spot any issues, it's time to replace the board as needed. The power supply board is a vital part of the Roper microwave's electrical system. When it malfunctions or gets damaged, it can lead to problems, including that unpleasant burning smell. By replacing the board when necessary, you can keep your Roper microwave running safely and free from any unusual odors. This simple action will help ensure your Roper microwave operates as it should.

View Roper Microwave Power Supply Board parts

3 Roper Microwave Thermostat

Most Common Solution
Repair Instructions:

After making sure your Roper microwave is free from any food scraps and the waveguide cover is undamaged, if you still notice a burning smell, it's possible that the thermostat is causing the issue. To investigate, take a close look at the thermostat for any signs of burn marks or damage. If you find any problems, it's time to replace the thermostat as needed. The thermostat is a crucial part of the Roper microwave that helps control the temperature. If it's not working correctly, it can lead to unwanted odors, such as the burning smell you're experiencing. Replacing the thermostat when required will help your Roper microwave function properly and without any unusual scents, ensuring your cooking experiences remain pleasant and safe.

How to Replace Roper Microwave Thermostat

  1. Prepare for the Replacement

    • Unplug the Roper microwave from the power source to ensure safety.
    • Clear the surrounding area and remove any items near the Roper microwave to create a clean workspace.
  2. Gather the Necessary Tools

    • Check the manufacturer's instructions or the Roper microwave's user manual to identify the specific tools required for the replacement. Typically, you may need a screwdriver, pliers, and possibly other specialized tools.
  3. Locate the Roper Microwave Thermostat

    • The thermostat is a safety device that monitors the temperature inside the Roper microwave and is usually located near the magnetron or the control panel.
    • Consult the Roper microwave's user manual or look for diagrams online to find the thermostat's location in your specific model.
  4. Remove the Roper Microwave Cover

    • Roper Microwave covers are typically secured with screws. Use the appropriate screwdriver to remove the screws and carefully lift off the cover.
    • Set the cover aside in a safe place.
  5. Identify the Thermostat

    • Once the cover is removed, locate the thermostat on the circuit board or inside the Roper microwave's interior.
    • The thermostat may be a small disc-shaped or rectangular component with wires attached to it.
  6. Disconnect the Wires

    • Take note of the wire connections on the thermostat, ensuring you remember how they are connected.
    • Using pliers, gently grip the wire connectors attached to the thermostat.
    • Carefully pull the connectors away from the thermostat to detach them. Take note of their positions and ensure you remember how they were connected.
  7. Remove the Old Thermostat

    • The thermostat may be held in place by clips, screws, or adhesive. Depending on the model, use the appropriate tools to release and remove the old thermostat.
    • Take care not to damage any surrounding components or wires during this process.
  8. Install the New Thermostat

    • Take the new thermostat and ensure it matches the specifications and dimensions of the old thermostat.
    • Position the new thermostat in the same location where the old one was removed.
    • If necessary, use clips, screws, or adhesive to secure the new thermostat in place.
  9. Connect the Wires to the New Thermostat

    • Attach the wire connectors to the corresponding terminals on the new thermostat.
    • Ensure a secure and proper connection by pushing the connectors firmly onto the terminals.
  10. Reassemble the Roper Microwave

    • Carefully place the Roper microwave cover back onto the Roper microwave and secure it with the screws.
    • Ensure all screws are tightened but not overly tightened.
  11. Test the Replacement

    • Plug the Roper microwave back into the power source.
    • Turn on the Roper microwave and run a test to verify that it is functioning correctly.
    • Check for any unusual heating patterns or issues with the Roper microwave's temperature.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Thermostat parts

4 Roper Microwave High Voltage Transformer

Common Solution
Repair Instructions:

Roper Microwave ovens work by generating a high voltage to power the magnetron antenna, responsible for cooking your food. When the high-voltage transformer malfunctions, it often produces sparks and a distinct burning smell. A word of caution: Roper Microwaves can store a dangerous amount of electricity, even when they're unplugged. Due to the high voltage and the risk of electric shock, attempting to replace electronic components like the high voltage transformer is extremely perilous. Therefore, it's crucial to leave this task to a licensed technician who has the expertise and equipment to handle it safely. If you detect the signs of a faulty high-voltage transformer, such as arcing and a burning odor, it's essential to act promptly. By relying on a qualified professional, you can address the issue while ensuring your safety remains a top priority.

How to Replace Roper Microwave High Voltage Transformer

  1. Prepare for the Replacement

    • Unplug the Roper microwave from the power source to ensure safety.
    • Clear the surrounding area and remove any items near the Roper microwave to create a clean workspace.
  2. Gather the Necessary Tools

    • Check the manufacturer's instructions or the Roper microwave's user manual to identify the specific tools required for the replacement. Typically, you may need a screwdriver, pliers, and possibly other specialized tools.
  3. Locate the Roper Microwave High Voltage Transformer

    • The high voltage transformer is responsible for converting the incoming electrical power to the high voltage required by the Roper microwave.
    • Consult the Roper microwave's user manual or look for diagrams online to identify the transformer's location in your specific model.
  4. Remove the Roper Microwave Cover

    • Roper Microwave covers are typically secured with screws. Use the appropriate screwdriver to remove the screws and carefully lift off the cover.
    • Set the cover aside in a safe place.
  5. Identify the High Voltage Transformer

    • Once the cover is removed, locate the high voltage transformer on the circuit board or inside the Roper microwave's interior.
    • The transformer is usually a large, rectangular component with wires connected to it.
  6. Disconnect the Wires

    • Take note of the wire connections on the transformer, ensuring you remember how they are connected.
    • Using pliers, gently grip the wire connectors attached to the transformer.
    • Carefully pull the connectors away from the transformer to detach them. Take note of their positions and ensure you remember how they were connected.
  7. Remove the Old High Voltage Transformer

    • The transformer may be secured with mounting screws or clips. Depending on the model, use the appropriate tools to release and remove the old transformer.
    • Take care not to damage any surrounding components or wires during this process.
  8. Install the New High Voltage Transformer

    • Take the new high voltage transformer and ensure it matches the specifications and dimensions of the old transformer.
    • Position the new transformer in the same location where the old one was removed.
    • If necessary, use mounting screws or clips to secure the new transformer in place.
  9. Connect the Wires to the New Transformer

    • Attach the wire connectors to the corresponding terminals on the new transformer.
    • Ensure a secure and proper connection by pushing the connectors firmly onto the terminals.
  10. Reassemble the Roper Microwave

    • Carefully place the Roper microwave cover back onto the Roper microwave and secure it with the screws.
    • Ensure all screws are tightened but not overly tightened.
  11. Test the Replacement

    • Plug the Roper microwave back into the power source.
    • Turn on the Roper microwave and run a test to verify that it is functioning correctly.
    • Check for any unusual behavior or issues with the Roper microwave's operation.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave High Voltage Transformer parts

5 Roper Microwave Main Control Board

Common Solution
Repair Instructions:

The primary control board in a Roper microwave might have a burnt component. You can check for this by examining the control board for any parts that look burnt or melted. If you discover such damaged components, it's important to replace the main control board. However, please be aware that Roper microwaves can store a significant amount of electricity, even after they've been unplugged. This poses a serious risk of electric shock. Therefore, attempting to replace electronic components in a Roper microwave, like the main control board, is extremely dangerous. For your safety, it is strongly recommended to have a licensed technician handle the replacement of the main control board. This ensures that the issue is addressed while prioritizing your well-being.

How to Replace Roper Microwave Main Control Board

  1. Prepare for the Replacement

    • Unplug the Roper microwave from the power source to ensure safety.
    • Clear the surrounding area and remove any items near the Roper microwave to create a clean workspace.
  2. Gather the Necessary Tools

    • Check the manufacturer's instructions or the Roper microwave's user manual to identify the specific tools required for the replacement. Typically, you may need a screwdriver and possibly other specialized tools.
  3. Locate the Roper Microwave Main Control Board

    • The main control board is responsible for managing the Roper microwave's functions and settings.
    • Consult the Roper microwave's user manual or look for diagrams online to identify the main control board's location in your specific model.
  4. Remove the Roper Microwave Cover

    • Roper Microwave covers are typically secured with screws. Use the appropriate screwdriver to remove the screws and carefully lift off the cover.
    • Set the cover aside in a safe place.
  5. Identify the Main Control Board

    • Once the cover is removed, locate the main control board, which is usually a large circuit board positioned at the front or back of the Roper microwave.
    • Take note of any connectors or wires attached to the control board.
  6. Disconnect the Connectors and Wires

    • Identify the connectors and wires attached to the main control board.
    • Gently pull the connectors and wires away from the control board to detach them.
    • Take note of their positions and ensure you remember how they were connected.
  7. Remove the Old Main Control Board

    • The main control board may be secured with mounting screws or clips. Depending on the model, use the appropriate tools to release and remove the old control board.
    • Take care not to damage any surrounding components or wires during this process.
  8. Install the New Main Control Board

    • Take the new main control board and ensure it matches the specifications and dimensions of the old board.
    • Position the new control board in the same location where the old one was removed.
    • If necessary, use mounting screws or clips to secure the new control board in place.
  9. Reconnect the Connectors and Wires

    • Attach the connectors and wires to their respective terminals or connectors on the new control board.
    • Ensure a secure and proper connection by pushing the connectors firmly onto the terminals.
  10. Reassemble the Roper Microwave

    • Carefully place the Roper microwave cover back onto the Roper microwave and secure it with the screws.
    • Ensure all screws are tightened but not overly tightened.
  11. Test the Replacement

    • Plug the Roper microwave back into the power source.
    • Turn on the Roper microwave and run a test to verify that it is functioning correctly.
    • Check for any unusual behavior or issues with the Roper microwave's operation.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Main Control Board parts

6 Roper Microwave Micro Switch

Common Solution
Repair Instructions:

After ensuring that your Roper microwave is free from food debris and that the waveguide cover is in good shape if you're still noticing a burning smell, it might be due to a shorted microswitch. To investigate, take a close look at the microswitch for any signs of burn marks or damage. You can also use a multimeter to check the microswitches for electrical continuity, which is like making sure they're allowing electricity to flow properly. If any of the switches show no continuity or indicate a short, it's a sign that the switch or switches need to be replaced. By addressing this issue, you can prevent the burning smell and ensure your Roper microwave operates as it should. It's a straightforward way to maintain your Roper microwave's performance and safety.

How to Replace the Roper Microwave Micro Switch

  1. Safety First

    • Prioritize your safety by disconnecting the Roper microwave from the power source. Unplug it from the wall outlet or turn off the circuit breaker dedicated to the Roper microwave.
  2. Identify the Micro Switch

    • Locate the micro switch within your Roper microwave. It is a small component typically found behind the control panel or near the door latch area.
    • Consult the Roper microwave's user manual or search for diagrams online to help you identify the micro switch's location.
  3. Remove the Control Panel or Access Panel

    • Depending on the Roper microwave model, you may need to remove the control panel or an access panel to access the micro switch.
    • Carefully remove the necessary screws or clips holding the panel in place, taking note of their positioning for reassembly.
  4. Disconnect Wires from the Micro Switch

    • Identify the wires connected to the micro switch. Note their positions or take a picture to assist with reconnection later.
    • Gently detach the wires from the micro switch. Some wires may have connectors that require you to release them by pressing or squeezing.
  5. Remove the Old Micro Switch

    • The micro switch is typically secured with screws or clips. Remove the screws or release the clips to detach the old micro switch from its mounting position.
    • Be cautious not to damage any surrounding components or wires during this process.
  6. Obtain a Replacement Micro Switch

    • Determine the specific micro switch model required for your Roper microwave. Check the Roper microwave's user manual or consult the manufacturer's website to find the correct replacement part.
    • Purchase the replacement micro switch from authorized dealers, appliance stores, or online retailers.
  7. Install the New Micro Switch

    • Take the new micro switch and position it in the same location where the old one was removed.
    • Secure the new micro switch using the appropriate screws or clips.
  8. Reconnect the Wires

    • Refer to the notes or picture taken earlier to guide you in reconnecting the wires to the new micro switch.
    • Ensure each wire is properly inserted into its corresponding connector or terminal.
  9. Reassemble the Control Panel or Access Panel

    • Attach the control panel or access panel back onto the Roper microwave, aligning it with the proper guides or slots.
    • Secure the panel with screws or clips, ensuring it is firmly in place.
  10. Reconnect the Power

    • Plug the Roper microwave back into the power source or switch on the dedicated circuit breaker.
    • Ensure the Roper microwave is receiving power.
  11. Test the Replacement

    • Turn on the Roper microwave and test the functionality of the micro switch.
    • Check if the Roper microwave responds correctly when operating the door latch or other relevant functions.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

Note: If you are uncertain or uncomfortable with any step, it is recommended to consult a professional technician or contact the manufacturer's customer support for guidance.

View Roper Microwave Micro Switch parts

7 Roper Microwave Magnetron

Common Solution
Repair Instructions:

The magnetron in a Roper microwave uses high voltage and high current DC power to create the Roper microwave energy needed to cook your food. If the magnetron gets damaged and burns out, it can lead to a noticeable burning smell, and your Roper microwave won't be able to heat your food. It's important to know that a burned-out magnetron cannot be repaired; it must be replaced. However, be cautious because Roper microwaves can hold a dangerous amount of electricity, even after they're unplugged. Due to the high voltage and the risk of electric shock, attempting to replace electronic components in a Roper microwave, like the magnetron, is extremely hazardous. Therefore, it's safest to entrust this task to a licensed technician who can replace the magnetron without compromising your safety.

How to Replace Roper Microwave Magnetron

  1. Prepare for the Replacement

    • Unplug the Roper microwave from the power source to ensure safety.
    • Clear the surrounding area and remove any items near the Roper microwave to create a clean workspace.
  2. Gather the Necessary Tools

    • Check the manufacturer's instructions or the Roper microwave's user manual to identify the specific tools required for the replacement. Typically, you may need a screwdriver, pliers, and possibly other specialized tools.
  3. Locate the Roper Microwave Magnetron

    • The magnetron is the main heating element of the Roper microwave and is usually located near the top or side of the Roper microwave's interior.
    • Consult the Roper microwave's user manual or look for diagrams online to identify the magnetron's location in your specific model.
  4. Remove the Roper Microwave Cover

    • Roper Microwave covers are typically secured with screws. Use the appropriate screwdriver to remove the screws and carefully lift off the cover.
    • Set the cover aside in a safe place.
  5. Disconnect the Magnetron Wires

    • Take note of the wire connections on the magnetron, ensuring you remember how they are connected.
    • Using pliers, carefully disconnect the wires from the terminals of the magnetron. Be gentle to avoid damaging the wires or terminals.
  6. Remove the Old Magnetron

    • The magnetron is typically held in place by mounting screws and brackets. Locate and remove the screws using the appropriate screwdriver.
    • Carefully detach the magnetron from any brackets or supports, taking note of its position and orientation for the replacement.
  7. Install the New Magnetron

    • Take the new magnetron and ensure it matches the specifications and dimensions of the old magnetron.
    • Position the new magnetron in the same location where the old one was removed, aligning it with any brackets or supports.
    • Use the mounting screws to secure the new magnetron in place, ensuring it is firmly attached.
  8. Connect the Wires to the New Magnetron

    • Attach the wires to the corresponding terminals on the new magnetron.
    • Ensure a secure and proper connection by firmly attaching the wires to the terminals.
  9. Reassemble the Roper Microwave

    • Carefully place the Roper microwave cover back onto the Roper microwave and secure it with the screws.
    • Ensure all screws are tightened but not overly tightened.
  10. Test the Replacement

    • Plug the Roper microwave back into the power source.
    • Run a test by heating a small Roper microwave-safe item to ensure the new magnetron functions correctly.
    • Check for any unusual noises, sparks, or issues during operation.
  11. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Magnetron parts

8 Roper Microwave Control Board

Common Solution
Repair Instructions:

The control board in your Roper microwave could have a burnt component. You can investigate this by closely examining the control board for any signs of parts that appear burnt or melted. If you do find any such damaged components, it's necessary to replace the control board. However, it's vital to be aware that Roper microwaves can retain a substantial amount of electricity, even after they've been unplugged. This poses a serious risk of electric shock. As a result, attempting to replace electronic components in a Roper microwave, such as the control board, is highly perilous. To ensure your safety, it is strongly advised to have a licensed technician handle the replacement of the main control board. This way, the issue can be addressed while prioritizing your well-being.

How to Replace the Roper Microwave Control Board

1. Safety First
- Ensure your safety by disconnecting the Roper microwave from the power source. Unplug it from the wall outlet or turn off the circuit breaker dedicated to the Roper microwave.

2. Identify the Control Board
- Locate the control board in your Roper microwave. It is typically found behind the control panel or inside the Roper microwave's interior.
- Consult the Roper microwave's user manual or look for diagrams online to help you identify the control board.

3. Remove the Control Panel
- Depending on the model, the control panel may be secured with screws or clips. Use the appropriate tools to carefully remove the control panel.
- Take note of any wires or connectors attached to the control panel and ensure they are disconnected properly.

4. Disconnect Wires from the Control Board
- Identify the wires connected to the control board. Take note of their positions or take a picture to assist with reconnection later.
- Gently detach the wires from the control board. Some wires may have connectors that require you to release them by pressing or squeezing.

5. Remove the Old Control Board
- The control board is usually secured with screws or clips. Remove the screws or release the clips to detach the old control board from its mounting position.
- Take care not to damage any surrounding components or wires during this process.

6. Obtain a Replacement Control Board
- Determine the specific control board model required for your Roper microwave. Check the Roper microwave's user manual or consult the manufacturer's website to find the correct replacement part.
- Purchase the replacement control board from authorized dealers, appliance stores, or online retailers.

7. Install the New Control Board
- Take the new control board and position it in the same location where the old one was removed.
- Secure the new control board using the appropriate screws or clips.

8. Reconnect the Wires
- Refer to the notes or picture taken earlier to guide you in reconnecting the wires to the new control board.
- Ensure each wire is properly inserted into its corresponding connector or terminal.

9. Reassemble the Control Panel
- Attach the control panel back onto the Roper microwave, aligning it with the proper guides or slots.
- Secure the control panel with screws or clips, ensuring it is firmly in place.

10. Reconnect the Power
- Plug the Roper microwave back into the power source or switch on the dedicated circuit breaker.
- Ensure the Roper microwave is receiving power and the control panel lights up.

11. Test the Replacement
- Turn on the Roper microwave and test the control panel buttons and functions to ensure they are functioning correctly.
- Check for any unusual behavior or issues with the Roper microwave's operation.

12. Clean up and Finish
- Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
- Return any items you removed from the surrounding area back to their original positions.

Note: It is important to exercise caution when working with electrical components. If you are unsure or uncomfortable with any step, it is recommended to consult a professional technician or contact the manufacturer's customer support for guidance.

View Roper Microwave Control Board parts

9 Roper Microwave Door Switch

Common Solution
Repair Instructions:

Many Roper microwaves come with three or four door switches. These switches work together when you close the Roper microwave door to make sure it's properly shut. But, if any of these door switches have burnt contacts or loose terminal connections, it can lead to a burning smell. To address this issue, you should check the door switches. If you notice a burnt smell or burnt connectors on the switch, it's a sign that the door switch needs replacing. Safety is vital when dealing with Roper microwaves. Even when unplugged, they can store a lot of electricity, which can be dangerous. So, to stay safe, it's best to have a licensed technician handle any replacements of electronic components like the door switch in your Roper microwave. This way, you can ensure the problem is fixed while keeping your safety a top priority.

How to Replace Roper Microwave Door Switch

  1. Prepare for the Replacement

    • Unplug the Roper microwave from the power source to ensure safety.
    • Clear the surrounding area and remove any items near the Roper microwave to create a clean workspace.
  2. Gather the Necessary Tools

    • Check the manufacturer's instructions or the Roper microwave's user manual to identify the specific tools required for the replacement. Typically, you may need a screwdriver, pliers, and possibly other specialized tools.
  3. Locate the Roper Microwave Door Switch

    • The door switch assembly is usually found near the latch mechanism inside the Roper microwave.
    • Consult the Roper microwave's user manual or look for diagrams online to locate the door switch assembly in your specific model.
  4. Remove the Roper Microwave Cover

    • Roper Microwave covers are typically secured with screws. Use the appropriate screwdriver to remove the screws and carefully lift off the cover.
    • Set the cover aside in a safe place.
  5. Identify the Door Switch Assembly

    • Once the cover is removed, locate the door switch assembly. It consists of multiple switches connected by wires and is typically mounted on a bracket.
  6. Disconnect the Wires

    • Take note of the wire connections on the door switch assembly, ensuring you remember how they are connected.
    • Using pliers, gently disconnect the wires from the switches. Be careful not to damage the wires during this process.
  7. Remove the Old Door Switch Assembly

    • The door switch assembly may be held in place by screws or clips. Depending on the model, use the appropriate tools to release and remove the old assembly.
    • Take care not to damage any surrounding components or wires during this process.
  8. Install the New Door Switch Assembly

    • Take the new door switch assembly and ensure it matches the specifications and dimensions of the old assembly.
    • Position the new assembly in the same location where the old one was removed.
    • If necessary, use screws or clips to secure the new assembly in place.
  9. Connect the Wires to the New Assembly

    • Attach the wires to the corresponding switches on the new door switch assembly.
    • Ensure a secure and proper connection by firmly attaching the wires to the switches.
  10. Reassemble the Roper Microwave

    • Carefully place the Roper microwave cover back onto the Roper microwave and secure it with the screws.
    • Ensure all screws are tightened but not overly tightened.
  11. Test the Replacement

    • Plug the Roper microwave back into the power source.
    • Close and open the Roper microwave door multiple times to ensure that the new door switch assembly functions correctly.
    • Verify that the door latches securely and that the Roper microwave operates as expected.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Door Switch parts

10 Roper Microwave Diode

Common Solution
Repair Instructions:

The diode in your Roper microwave has an important job it converts the electrical power from the transformer, changing it from one form (AC) to another (DC), and doubles the voltage to about 5,000 volts. This high voltage is what gives the magnetron, the part that heats your food, the power it needs. If the diode gets damaged or burns out, it can't provide the necessary voltage to the magnetron, which means your Roper microwave won't be able to heat your food. Sometimes, you can see that the diode is visibly burnt. To check if the diode is the problem, you can inspect it. If it looks burnt, it's time for a replacement. But if you can't tell just by looking, you can test it with a multimeter or a 9-volt battery to see if it's working as it should. Remember, Roper microwaves can store dangerous amounts of electricity, so it's best to let a licensed technician handle diode replacements for your safety.

How to Replace Roper Microwave Diode

  1. Prepare for the Replacement

    • Unplug the Roper microwave from the power source to ensure safety.
    • Clear the surrounding area and remove any items near the Roper microwave to create a clean workspace.
  2. Gather the Necessary Tools

    • Check the manufacturer's instructions or the Roper microwave's user manual to identify the specific tools required for the replacement. Typically, you may need a screwdriver, pliers, and possibly other specialized tools.
  3. Locate the Roper Microwave Diode

    • The diode is typically located near the magnetron, which is the main heating element of the Roper microwave.
    • Consult the Roper microwave's user manual or look for diagrams online to locate the diode in your specific model.
  4. Remove the Roper Microwave Cover

    • Roper Microwave covers are typically secured with screws. Use the appropriate screwdriver to remove the screws and carefully lift off the cover.
    • Set the cover aside in a safe place.
  5. Identify the Diode

    • Once the cover is removed, locate the diode on the circuit board. It is usually a small cylindrical or rectangular component with two wires connected to it.
  6. Disconnect the Diode

    • Use pliers to gently grip the wire connectors attached to the diode.
    • Carefully pull the connectors away from the diode to detach them. Take note of their positions and ensure you remember how they were connected.
  7. Remove the Old Diode

    • The diode may be held in place by clips, screws, or adhesive. Depending on the model, use the appropriate tools to release and remove the old diode.
    • Take care not to damage any surrounding components or wires during this process.
  8. Install the New Diode

    • Take the new diode and ensure it matches the specifications and dimensions of the old diode.
    • Position the new diode in the same location where the old one was removed.
    • If necessary, use clips, screws, or adhesive to secure the new diode in place.
  9. Connect the New Diode

    • Attach the wire connectors to the corresponding terminals on the new diode.
    • Ensure a secure and proper connection by pushing the connectors firmly onto the terminals.
  10. Reassemble the Roper Microwave

    • Carefully place the Roper microwave cover back onto the Roper microwave and secure it with the screws.
    • Ensure all screws are tightened but not overly tightened.
  11. Test the Replacement

    • Plug the Roper microwave back into the power source.
    • Turn on the Roper microwave and run a test to verify that it is functioning correctly.
    • Check for any unusual noises or issues during operation.
  12. Clean up and Finish

    • Once you have confirmed that the replacement is successful, tidy up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Diode parts

11 Roper Microwave Relay Board

Common Solution
Repair Instructions:

After making sure your Roper microwave is free from any leftover food particles and the waveguide cover is in good shape, if you still notice a burning smell, it's possible that the relay board is the source of the problem. To investigate, take a close look at the relay board for any signs of burn marks or damaged components. If you find any issues, it's time to replace the relay board as needed. The relay board is a crucial part of the Roper microwave's electrical system, and when it malfunctions or gets damaged, it can lead to problems like the burning smell you're experiencing. By replacing the board when necessary, you can keep your Roper microwave running safely and free from any unusual odors. This simple action will help ensure your Roper microwave operates as it should.

How to Replace Roper Microwave Relay Board

  1. Safety First

    • Prioritize your safety by disconnecting the Roper microwave from the power source. Unplug it from the wall outlet or switch off the dedicated circuit breaker.
  2. Identify the Relay Board

    • Locate the relay board in your Roper microwave. It is typically positioned inside the control panel area or behind the control panel itself.
  3. Order the Correct Replacement Relay Board

    • Determine the specific model and type of relay board required for your Roper microwave. Refer to the user manual or contact the manufacturer to obtain the correct replacement part information.
    • Purchase the replacement relay board from authorized dealers, appliance stores, or online retailers.
  4. Prepare the Workspace

    • Clear a clean and spacious area to work on the replacement. Place a soft cloth or towel on the surface to protect the Roper microwave and surrounding area from scratches.
  5. Access the Relay Board

    • Depending on your Roper microwave model, you may need to remove the control panel, back panel, or other components to access the relay board. Consult the user manual or search online for specific disassembly steps tailored to your model.
  6. Disconnect the Old Relay Board

    • Identify the wiring connections to the old relay board. Carefully disconnect the wires, ensuring you remember their original positions.
    • Remove any screws or mounting brackets securing the relay board to the Roper microwave. Take note of their locations for reassembly.
  7. Install the New Relay Board

    • Align the replacement relay board with the corresponding mounting points in the Roper microwave.
    • Connect the wiring to the new board, ensuring each wire is securely attached according to the color-coded or labeled connections.
  8. Reassemble the Roper Microwave

    • Follow the reverse order of the disassembly steps to reassemble the Roper microwave. Ensure all components, panels, and covers are properly aligned and fastened according to the manufacturer's instructions.
  9. Reconnect the Power

    • Plug the Roper microwave back into the power source or switch on the dedicated circuit breaker.
    • Verify that the Roper microwave is receiving power.
  10. Test the Replacement

    • Turn on the Roper microwave and check if the relay board is functioning correctly. Test various Roper microwave functions, such as heating, timer, and control panel operation, to ensure they are working as expected.
  11. Clean up and Finish

    • Once you have confirmed that the replacement is successful, clean up your workspace and discard any packaging or old parts.
    • Return any items you removed from the surrounding area back to their original positions.

View Roper Microwave Relay Board parts

12Interior Cavity not Clean

Repair Instructions:

To prevent food from making a mess inside your Roper microwave, it's a good practice to cover it when you're cooking. If you leave food residue in the Roper microwave, it can keep cooking every time you use it. Over time, this can lead to an unpleasant burning smell. So, after every use, make sure to clean up any spills or splatters. By covering your food and promptly wiping away any mess, you can maintain a clean and odor-free Roper microwave. It's a simple way to ensure that your Roper microwave stays in good condition and continues to serve you well, without the annoyance of unwanted smells.

View Roper Interior Cavity not Clean parts
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store