Removed unit from wall and took outer shell off, de-energized capacitor and then took a multi-meter and tested all the High voltage parts and magnetron. They tested out fine other than the diode and then I looked at the "Safety" circuit if you will the power loop that goes through door switches and thermostats to energize the High Voltage transformer and magnetron. Turns out the thermostat that is on the side of the magnetron wasn't closed, so I took a butane torch and heated it up past the... Read more
Removed the door cover; 3 screws on one side. Two screws to remove the old and install the new. Needed pliers to hold the broken part to remove old screws. Read more