Kenny for Model Number SHX45P05UC/62 Unit runs for less than 30 minutes and shuts off. Power switch does nothing...no indicators lit. After it cools down it comes back to life. If the machine was running, and you don't open the door and if you wait long enough the unit will come back on but at the original run time. If I remove the front panel and take the control board out and hang it in open air it runs fine. Something must be overheating on the board and causing it to fail. Can anyone tell me what could be overheating on the board? I am an engineer and I can fix it but I was hoping someone could help me avoid all of the reverse engineering and debugging. If I have to replace the board fine but if anyone has actually debugged it down to the component level, that would be genius. Thanks,
Answer Kenny, With this issue it will most likely be caused by a faulty control board. The control board may have a relay or a solder joint that is bad and would cause this issue to occur. A control board would be the part needed. Read More... Answered by AppliancePartsPros.com | Friday, January 26, 2018