Eb5 for Model Number RDSS30QB This is a follow up to our prior Q&A (pasted below)...I went ahead and replaced the spark module with the correct one from your store. All 4 gas burners now light (good news) but as soon as I flipped the power back on, all 4 burners started to continuously spark (even without turning any knobs and even after I tested and lit each burner--they won't stop sparking). Is this an issue with the new module or is something else going on? Please help/advise how to figure this out--I am not electrically savvy but determined to win this battle! Thank you. Prior question you answered--Over time, Thermador gas range no longer sparking any of 4 burners. Replaced all 4 igniters and 2 ignition switches. Now getting sparks on 3 of 4, but not strong enough to light the gas. The connectors on the wires attaching to the bottom of the igniters show varying degrees of corrosion/browning inside, whereas the connectors at the spark module end look fine. Might I just need to replace the 4 wires and not the module to get a stronger spark to the igniters? If so, where can I purchase just the wires with the correct connectors--I have not been able to find them on the site? Thank you in advance for any help or suggestions!
Answer EB5, the spark module would need to receive voltage from a valve switch being turned to the on position. Testing each switch for continuity when they are in the off position will allow the identification of which switch has failed. Read More... Answered by AppliancePartsPros.com | Tuesday, November 9, 2021