Mr. Reed for Model Number 79096002600 My question is in regards to the Infinite switch. One of my tenants was having an issue with the front left element getting red hot no matter what the temp was set to. I replaced the switch and now the element works but will not get hot enough to glow red. I also replaced the element but it did not change the results. Are the infinite switches the same for both the small and large burners on this model? is there any other reason why the element would not go up to high? any help would be greatly appreciated. Thank you!
Answer Mr. Reed, The infinite switches are different for the burners. The infinite switch for the 6 inch burner is 316436000 and the larger 8 inch burner switch is 5303935086. Our information indicates the left front element is a large element 316135401, if you installed a small element infinite switch 316436000 on a large element 316135401 the element will not reach temperature, the infinite switch will cycle early due to the difference in the wattage and amperage draw. Recheck and make sure you have the correct switch installed. Read More... Answered by AppliancePartsPros.com | Monday, September 14, 2015