Chris for Model Number FEF368GCA The switch for the Dual burner right front element has different labels on it. How do I test to this switch for continuity? The labels on the back of the switch are, in clockwise order, P1, 2, P2, 4a, 4. Thanks for your help
Answer Chris, If you turn the knob on the dual element on there should be resistance between Terminals P1 to 2 and if you turn it to the dual setting there should be continuity from P2 to terminal 4 and P2 to terminal 4a. Read More... Answered by AppliancePartsPros.com | Friday, May 19, 2017