Troy for Model Number PFSF6PKXEWW I am a local handyman trying to figure out why the freezer was warm and fresh food cool froze and no evap funs running torpor bottom. I have replaced the fresh food evap fan motor and the main control board but still only compressor comes on and no evap fans working. Please help!!
Answer Troy, On these units when the door has opened the fans will shut off. You will want to tape off the door switches and see if the fans come on with the door open. If they do then check the frost pattern on the evaporator coils to make sure that there is not a defrost issue which would be indicated by an impacted evaporator. If the coils have very little frost then a service technician will need to check the unit to determine where the sealed system is leaking or restricted. Read More... Answered by AppliancePartsPros.com | Monday, November 11, 2019