Robert for Model Number GE fridge GTS18GBSARWW Fridge and freezer stopped cooling over night. Fridge temp approx. 50, freezer food half defrosted. Light on, no compressor, cond. fan or evap fan. running. Moved temp control both ways, nothing. Unplugged, re-plugged, nothing. Emptied unit. Moved unit out, comp. cold to touch. Cleaned condenser. 5 minutes later while scratching head, unit turned on. Cond. fan and evap fan running. Whats up?? Stuck defrost control? WR09X10049 Stuck defrost t-stat? WR50X10021 OR ??? THANK YOU
Answer Robert, Based on the issue it sounds like the unit did stick in the defrost cycle. This would be caused most likely by a defrost control part number WR9X502. Read More... Answered by AppliancePartsPros.com | Friday, December 12, 2014