Mr. Bigalsworth for Model Number WMR04GAVBBB I have a GE mini fridge that I got from someone else. It stopped working and I feel determined to get it working again. I feel I can learn something new and save money instead of buying new. It doesn't get cold. The motor runs. I replaced the relay because it looked burn up. The temperature selector was pulled down as if they looked into it being that. But I'm not certain. Because it doesn't push any cool air out. I can feel it running.
Answer Mr. Bigalsworth, If the compressor is running and the evaporator coil is not getting cold, then the unit will have a sealed system issue. It my be a leak, a restriction or faulty compressor. The sealed system parts for this unit is not available. Read More... Answered by AppliancePartsPros.com | Tuesday, May 14, 2013