Customer Questions and Answers for Refrigerator Defrost Timer by Ge

4.89 (64)
By: Ge
Part Number: OEM6185133
Manufacturer Part Number: WR9X502

Refrigerator not cooling or ice building up on evaporator coils? The defrost timer controls the defrost cycle. DIY-friendly, installs in 5 minutes.

More
$77.95

IN STOCK
Ships Monday Guaranteed
Add to Cart

Questions & Answers

For Ge Refrigerator Defrost Timer (Part Number: OEM6185133)

View all Questions

Answer

Jim, The original defrost timer had a 35 minute defrost cycle, the replacement defrost timer has a 25 minute defrost cycle. These are the "total" defrost cycle times. The defrost heater is controlled through the defrost heater and opens at 53 degrees regardless of time(usually takes 10 to 15 mins.). Once the thermostat opens and "turns the defrost heaters off " the remainder of the total defrost tome is used to evacuate the defrost water and condensation into the drain pan, then the compressor should start, run and start cooling.

Read More...

Answered by AppliancePartsPros.com   |   Wednesday, May 22, 2019

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google