Mickey for Model Number GTS16DBEJRWW Frig in garage. We in S Texas, where very warm. Have a temperature sensor in freezer to monitor temperatures. Monitor has Hi alarm, set it to 25 deg F. Also history of both low n high temperatures. Alarm went off, and freezer temperature displayed ~50 deg F Noticed temperatures range -3/4 to 8/10. However once upon a time in 12 hr period, hits the 50s. And when it does, the freezer temperature drops at fast pace. Condenser coil clean, its fan in bottom rear running ok. And because warm in garage set small fan in front, hope blowing air over condenser coil. Installed new thermostat yesterday but overnite beeping, and saw 56 deg! What I don’t know is the time the the defrost time kills compressor and fan while in the defrost mode. Any suggestions? Replace defrost timer?
Answer Mickey, The defrost timer will typically be an 8 hour timer and cycle every 8 hours. It could be that the defrost timer is faulty and would need to be replaced. Read More... Answered by AppliancePartsPros.com | Wednesday, July 21, 2021