Thomas for Model Number Hotpoint CTX14AYBRWW The defrost blower is constantly turning on throughout the day multiple times beyond normal. There is no frost inside and the fridge keeps proper temp. Many times the blower keeps restarting (revs up and down repeatedly) while trying to start. What could be the culprit ?
Answer Thomas, the refrigerator door gasket OEM13239452 may need to be inspected to identify if it has a gap that may be allowing warm air to enter the refrigerator and cause it to cycle more frequently. Read More... Answered by AppliancePartsPros.com | Thursday, October 10, 2024