Brian for Model Number PSC25PSTASS Digital control panel set for 37 for fridge but digital temp display shows temp as 44. Was going to replace the temp sensor in fridge cabin but used an instant read temp guage to comfirm That cabin temp is accurate. What would cause the control panel to be off? I would think if control panel/board is broke it would cease to work at all rather than readout being off by a few degrees. I can go ahead and replace the sensor for a few dollars but that doesnt make logical sense, and it doesnt seem economical to replace a 200 dollar control panel board for a digital readout thats off six digits. Any ideas to get readout in synch with actual temp?
Answer Brian, Unfortunately there is no way to get the control board to sync with the actual temp of the unit. This issue would not be in the display board but would be with the main control board not sending a good signal to the display board or not reading the thermistor properly. You can check to make sure that the thermistor is not off. The resistance values for the thermistor would be 42.2K at 0 degrees, 12.7K ohms at 41 degrees, 10K ohms at 50 degrees and 5K ohms at 77 degrees. Read More... Answered by AppliancePartsPros.com | Friday, March 20, 2015