Ej for Model Number PSS26NGPAWW About a month ago, I replaced the main board because the compressor was not working, which solve the problem. Now, everything is off except the light on the refrigeration side. I thought the new main board was defective, but when I replaced it with the old board, I got the same results, everything off except the light. Do you think it's the Interface Control Panel that needs to be replaced?
Answer Ej, The interface panel would not cause the unit to not have lights or fans or the compressor. You will want to test for power into the main board. If there is no power then test to make sure that there is 120 vac at the wall outlet. If there is then check where the power cord connects to the unit to make sure that there is 120 vac and if there is not then it would be a faulty cord if there is then would be a harness issue in the cabinet. There is power either being lost or a faulty main control board. Read More... Answered by AppliancePartsPros.com | Thursday, March 9, 2017