Jennifer for Model Number PDS22SCRBLSS My g.e. profile bottom freezer fridge won't stay cool. It's temp keeps fluctuating up and down. And sometimes when we open it the lights come on sometimes they stay off. We cleaned the coils and also made sure that there was enough freon in it, because the compressor was very hot when we finally checked the coils tried diagnostic mode but it keeps telling me to press a third button that's not a temp button but there is no other buttons.
Answer Jennifer, it would be recommended that the main control WR55X10942C is tested for a continuous 120VAC supply from the power cord. If there is proper voltage, the next step would be to test the black wire going to the compressor for 120VAC when the unit is not reaching the proper temperature. If there is 120VAC but the compressor does not cause a proper frost pattern on the evaporator (light frost coating on the entire evaporator within an hour), it would be likely that there is a sealed system failure that would require an EPA certified tech to diagnose and repair. Read More... Answered by AppliancePartsPros.com | Sunday, August 22, 2021