J. Gross for Model Number PGP990SEN1SS I have a 9 yr old GE Profile natural gas cook top that used to work great for about 3 years. Now the 4 burners will only light occasionally with the spark. There is gas at all burners, and the igniters spark on each one. On two of the burners the spark seems to be a little intermittent, but not a lot. Oddly, if I blow on the burners with the igniters on, then they will light. What could this be?
Answer J. Gross, First, remove the burner caps, and check the burner bases to make sure they're clean, free of rust or corrosion, and there's no debris in the burner area(s). Look down inside the burner base and look to see if there is any debris or grease, spillage that may be interfering with the gas flow from the burner tube orifice. Turn off the gas supply and check that the sparks are a bright "white" color when the burner valve/switch is turned on and the spark is "striking" the same spot on the burner, consistently. You didn't mention if the range operates on Nat gas or LP gas, but blowing air towards the burner changes the fuel/air mix, Read More... Answered by AppliancePartsPros.com | Monday, May 21, 2018