Earsene for Model Number Jb2500f4cc Heating elements work but on right front burner not working. Switched element and element works on back burner. What is not working on right front burner.
Answer Earsene, based on the information provided, the failure is going to be with the burner switch WB24T10025 or with the element terminal block WB17X210. With the range power cord unplugged, the switch can be set to a heat cycle and tested for continuity from the terminal L1 to H1, then from L2 to H2. If there is not continuity, the switch has failed. If there is continuity, then the terminal block has likely failed. Read More... Answered by AppliancePartsPros.com | Thursday, October 1, 2020