Skip to Content
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • lovely images 15 million satisfied customers
  • boxes images Over 2.1 Million Parts In Stock
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store

Customer Questions and Answers for Door Interlock Switch by Ge

4.89 (64)
By: Ge
Part Number: OEM7867365
Manufacturer Part Number: WB24X10047

The Door Interlock Switch is an OEM part for GE microwaves. It ensures the safety of the microwave by preventing the appliance from operating while the door is open. This switch is part of a microwave's safety mechanism, which includes multiple interlock systems designed to stop the generation of microwaves immediately once the door is opened, thereby protecting users from exposure to microwave radiation.

Signs that it's time to replace your door interlock switch include the microwave not starting or stopping unexpectedly, the microwave continuing to operate with the door open, or a failure to heat food even though the appliance seems to be running. 

Symptoms of a bad Door Interlock Switch include:

  • Microwave does not start
  • Microwave stops unexpectedly
  • The microwave operates with the door open
  • Microwave turns on but does not heat food

This OEM GE part can also be used on Hotpoint, RCA, and Kenmore/Sears appliances. 

More
$31.95
Compare At:
$38.02
You Save:
$6.07

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Ge Door Interlock Switch (Part Number: OEM7867365)

View all Questions

Answer

Hello Ernest. You most likely have a "high voltage" side malfunction. Transformer, diode, magnetron, Capacitor. You will need to be extremely careful if you decide to test the components with a multi meter, Very high residual voltage is present, so make sure you remove power to the microwave and short across the terminals on the capacitor. The magnetron should have a reading of less than 1 ohm resistance across the two terminals, and an "open" circuit between each terminal and chassis ground. The diode/rectifier should have a resistance reading in one direction only, no resistance, or resistance in both directions indicate a faulty diode. The primary winding on the trans former should read approximately 450 Ohms resistance, the secondary winding should read 80 ohms resistance, and the filament transformer should read 100 ohms resistance. If all the readings are proper and in range, replace the magnetron.

Read More...

Answered by AppliancePartsPros.com   |   Wednesday, September 10, 2014

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store