Jeff B for Model Number PSS25SGNABS Both the refridgerator side, and freezer side will not cool. The motor is running, and I have unplugged it and plugged it back in. Also I have cleaned the coils. Both sides are currently at room temp.
Answer Jeff, You will need to check to see if the compressor is running. If the compressor is not running, at the main control board, verify power going to the compressor and also check at the compressor by testing across the wires on the start relay and overload. If there is power there then the most likely cause of failure is the start relay WR07X26749 in which you would want to replace the overload WR08X10025 at the same time. If there is no power from the board then you would need to replace the control board. Read More... Answered by AppliancePartsPros.com | Wednesday, September 18, 2013