Debbie for Model Number GSHS9NGYBCSS I had replaced the temperature sensor and defrost thermostat 3 weeks ago. I noticed the refrigerator and freezer were getting warmer and frost was building up on the back panel again. Any suggestions?
Answer Debbie, it would be recommended that the freezer thermistor WR55X10025 and the refrigerator thermistor WR55X10025 are tested for resistance as they can cause this issue. At 77°F they should measure 5kO, at 59°F they should read 7.8kO, at 41°F they should read 12.7kO, and at 23°F they should measure 21kO. If they test good, the next step would be to test the defrost heater WR51X10055 as it should measure 18O. If these items test good, the failure would be in the main control WR55X10956. Read More... Answered by AppliancePartsPros.com | Monday, December 28, 2020