Kirk C for Model Number WM1812CW Get OE error message,replace drain hose and cleaned filter,casing and pump. Put 110 volts to pump and it runs. Put back together and OE message.
Answer Kirk, You will want to pull the hose from the bottom of the tub and check to see if it is clogged. If not clogged then check the impeller on the drain pump to make sure that the impeller is not damaged and make sure that it is not loose. Also check the resistance of the pump which should be between 10 to 20 ohms. If not then replace the drain pump. Check the pressure hose to make sure that the hose is not clogged and the air dome is not clogged. Check the pressure switch to make sure that it is resetting. Read More... Answered by AppliancePartsPros.com | Thursday, August 15, 2013