Matt for Model Number lg lfxs27466s Last night I noticed water on the top of the freezer drawer door and realized that the ice in the door was melting, I checked the temperature inside and the fridge was about 54, and the freezer was about 39. I pulled the back off and the coils and fan were really dusty, cleaned it all off and ran the push button test and everything worked OK. I plugged it back in and put a thermometer in the freezer and it went from about 59 to 27.9 in around 3 1/2 hours. But then the temperature jumped to around 50. I let it run overnight and the temperature slowly dropped but bottomed out around 39.9. I’ve taken the freezer back panel off and the coils are not frosted but they were wet. All the fans are working OK. I’m hoping it’s the overload compressor or the PCB. I tested the overload compressor and it has continuity and it reads .7 ohms. Any ideas? Thanks!!
Answer Matt, If the compressor is not running then this would most likely be a faulty relay on the compressor but if the temperature is getting down to 39 degrees in the freezer then this sounds more likely that you have a sealed system issue and will need to have service. Read More... Answered by AppliancePartsPros.com | Monday, October 25, 2021