Refrigerator stopped cooling after power outage? The compressor overload protector prevents overheating damage. Easy DIY fix when compressor won't run.

More
$45.85

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Lg Refrigerator Compressor Overload Protector (Part Number: OEM15995952)

View all Questions

La for Model Number LFXS29766/01

This LG refrigerator was displaying 6 flashes from the LED on the control board. My research stated either a bad board or something in the defrost system. I replaced the board & the compressor ran for approximately 3-5 minutes, then kicked off & the 6 flashes returned on the new board. I spoke w/ 1 of your techs & they suggested to replace the compressor overload harness which has shipped. I pulled the existing harness & have continuity on the wiring & have .5 in resistance on the overload. Any suggestions?

Answer

Hello LA, thank you for contacting APP,

A 6-blink code indicates a failure of the main control or the compressor. The overload may be weak and is opening prematurely. I would recommend unplugging the unit, disconnecting the 3-wire plug at the compressor, and taking a resistance reading from each of the pins on the connector to the others, these should all read 7.2-9.2Os resistance. Also, check that the condenser fan is running properly and the condenser itself is clean and clear of any debris. If all of this appears to be correct I would continue with replacing the overload.
If the compressor is reading out of range then it will need to be replaced by a certified sealed system technician.
If the condenser fan is not running when it should be then the DC Motor EAU63103301 / EAU63103301 will need to be replaced.
If the condenser coil is dirty/obstructed it will need to be cleaned.
If all else checks as good and replacing the overload does not resolve the issue I would suspect a sealed system issue which will need to be verified by a certified sealed system tech.

Read More...

Answered by AppliancePartsPros.com   |   Tuesday, August 27, 2024

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google