Questions & Answers

For Lg Washer Rotor Position Sensor Assembly (Part Number: OEM21045243)

View all Questions

Lg Tromm-2005 for Model Number LG WM2277HW 2005 model

At wash cycle start, the tub begins filling with water. After @ 2 minutes, it attempts to turn the tub one way, then the other. As it is trying to turn, it moves a degree or two and stops as if it has met resistance. After a minute or two of this it stops and error message LE is displayed. Note-the tub does turn easily by hand, either direction. I doubt this has any bearing, but the unit makes a noise as it is attempting to turn CCW. The noise most resembles the sound of a copper water pipe system just barely turned on-like water flowing. It makes little noise as it attempts to turn CW. I've unplugged the unit and left it unplugged for 2-3 minutes and turned the tub 3-4 revolutions in each direction, with no perceivable difference in effort. This seemingly began with no warning. I am about to pull the unit away from wall and pull back off to try and shed more light on situation as I'm guessing the issue may be related to the motor or its components. Thanks for your help!

Answer

LG Tromm-2005, The LE indicates a locked motor error. You will want to check the following. • The connector (3-pin, male, white) in the MOTOR HARNESS is not connected to the connector (3-pin, female, white) of STATOR ASSEMBLY. • The electric contact between the connectors (3-pin, male, white) in the MOTOR HARNESS and 4-pin, female, white connector in the MAIN PWB ASSEMBLY is bad or unstable. • The MOTOR HARNESS between the STATOR ASSEMBLY and MAIN PWB ASSEMBLY is cut (open circuited). • The hall sensor is out of order/defective.

Read More...

Answered by AppliancePartsPros.com   |   Monday, December 30, 2013

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store