Brian for Model Number DV42H5000EW/AE04 On any cycle, if the time is 45 min. It runs for a little, then time jumps down to 2 min could this be the board?
Answer Brian, it would be recommended that the sensor bars are thoroughly cleaned to ensure they are not providing incorrect information to the control. From there, the dryer thermistor DC32-00007A would need to be tested for resistance and it should measure around 10K Ohms of resistance at room temperature. If this checks good, the most likely cause of failure would be the main control DC92-01596D. Read More... Answered by AppliancePartsPros.com | Tuesday, December 21, 2021