Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Refrigerator Inverter Control Board by Samsung

4.89 (64)
By: Samsung
Part Number: OEM16747761
Manufacturer Part Number: DA92-00111B

Fixes refrigerator not cooling or compressor not running. Controls inverter system for efficient operation. Common fix after power surges. DIY-friendly.

More
$241.95

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Samsung Refrigerator Inverter Control Board (Part Number: OEM16747761)

View all Questions

Gino for Model Number RF267AERS/XAA

Hello, I have a samsung RF267AERS/XAA fridge. Two weeks ago we were told that the breaker was thrown on that circuit, not sure if the issue was too much pull, as a few appliances were being used in the house, but not on the same circuit to my knowledge. A few days later I noticed the unit getting warmer with the temperature flashing on the display. I checked the back and the compressor fan was spinning but the compressor was not on. The inverter board was flashing 5x (under voltage). within 24hours of that, the unit started working again and it cooled the fridge down to normal working conditions. Inverter board had a solid led when compressor was on, and we thought the issue had resolved itself. A few days later it happened again. Same flashing light error (5x led light). Again within 24hrs the unit started working again, and as of today it has stopped cooling again. I assume it may start again sometime soon. I notice now that when it stops working, the temperature on the display stays at -2 and 38 even though the unit is warmer, the temps do not reflect reality until you power cycle the unit. I've tried to source the problem by replacing the main board with a used one, and checking voltages and resistance, but the issue persists. I'm a little stumped. Resistance on compressor measured 8.9 ohms across all three pins Voltages on inverter board: s/blue / grey =120VAC red / brown = 0VDC btw: the samsung troubleshooting manual for compressor not working is inaccurate and may not be related to this unit, as it asks to check IC's that do not exist on this main board. Upon first plugin in the unit, the inverter led quickly flashes 2x, then the led shuts down until the compressor is called or I do a forced FF test, then it starts its 5x blink cycle. Also a relay on the upper left hand of the main board clicks and flashes twice right after plugin in, but nothing happens.

Answer

Gino,

According to the information that can be located, the 5 flashes indicate that there is low voltage. You will want to replace the inverter board and if this problem persist then it would be the compressor but since it is a sporatic issue the inverter would be the most likely issue.

Read More...

Answered by AppliancePartsPros.com   |   Thursday, December 2, 2021

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google