Willis for Model Number RB2044SL Refrig temp display on outside of door indicating accurate temp of freezer 34 deg ff dept 56 deg. Upon unplugging and re-plugging unit starts and get back down to normal temps freezer 0 - 5 deg ff to 34 -36 deg. This is necessary to do every 4 hrs approximately. It will not restart after cycling once. The control board has been replaced. Not sure where to check next. Local repairmen thought the control board was faulty, so it was replaced and still does same thing.
Answer Willis, You will want to test the sensors in the unit to see if they are faulty. The resistance for the thermistor should be 5K at room temperature. Read More... Answered by AppliancePartsPros.com | Monday, September 12, 2016