Donnie for Model Number RB215LABP Freezer section is too cold (-21F). Set for 8F. Refrigerator section temp is correct. Found evaporator in refrigerator section frozen solid blocking drain. Defrosted and restarted unit. Freezer section still running too cold. Freezer evaporator was clear. Freezer sensor showing 13,320 ohms when submersed in 32F degree water for ten minutes. Panel was not set to fast (super) freeze. Been an ongoing issue for awhile. Any help? Thanks!
Answer Donnie, if the thermistor tests for 49,848 Ohms at the temperature reached in the freezer when testing from the main control, the failure would be the control board DA41-00293A. Read More... Answered by AppliancePartsPros.com | Tuesday, September 28, 2021