Steve1147 for Model Number mvwx600xwo Washer wouldn't begin any cycle, just "click....thump". Ran the diagnostics, all goes well to step 8 (shifter moves to agitation position), again, "click...thump" for about 2 minutes, then No agitation as it should. Pump drains unit, then step 11 (shifter moves to spin position) same 2 minutes of click...thump, then motor doesn't spin as it's suppossed to. Lid unlocks and diagnostics is over. Is this the actuator? (I also ran calibration on it twice, no help) Thanks, Steve
Answer Steve, Sounds like a loose connection at the shifter or motor. You'll need to check the circuit resistance with a multi meter TJMA-DMT3 and here's some meter usage information [http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html]. It sounds like you've accessed the tech data information, so you should ahve access to all the test information. Thanks Read More... Answered by AppliancePartsPros.com | Tuesday, June 26, 2012