Levi for Model Number LGR7648PQO When I turned on the dryer, it ignited and flame followed for two minutes, then the flame turned off. After a minute the igniter turned on but the flame doesn't come out. This happened even with the vent not connected.
Answer Hello Levi, This sounds like one of the coils 279834 on the safety valve has failed. Read More... Answered by AppliancePartsPros.com | Monday, June 25, 2012