Yankeefan for Model Number KitchenAid Refrigerator KSRS25ILBL Refrigerator side warm, approx. 52 degrees, freezer side was fine, all items were frozen solid. I noticed there was frost on the back bottom of the freezer wall, so a repairman was called. He pulled off the back panel inside the freezer (covering the coil), and used a hairdryer to remove the ice which had formed on the coil. He replaced the defrost thermostat (he called it a defrost relay), and said that our refrigerator would work for approx. 4 to 5 days, until he could get back with a new control panel (he called it a computer). Why would the defrost "relay" only work for 4 to 5 days until the "computer" arrives? Is it possible that it will take 4 to 5 days for ice to form over the coil again? Also, there was no air coming out of the diffuser (refrig side) until the coil was de-iced. Now there is air coming out (top left side of refrigerator) of the diffuser. Any suggestions or guidance on whether or not the control panel needs replacing will be appreciated. A side note, the current control panel was installed in 2009, after an electrical short blew out the original one. Thanks.
Answer Yankeefan, It does sound like your refrigerator has a defrost issue, and presume the servicer found the defrost thermostat "open" when iced over. Yes, if there is an issue with the main control board 8201658 the refrigerator will cool until the evaporator coils clog with ice again, which can take 3 to 5 days, depending on usage. If you wish, remove the lower kick plate grille, you should find the tech data information sheet attached to the lower frame work of the refrigerator cabinet. You can review the instructions, and program into the "service Diagnostics Mode" and test all the components of the cooling system including the defrost cycle. Read More... Answered by AppliancePartsPros.com | Tuesday, March 4, 2014