Answer

Hello Satish,
You should run a diagnostic cycle to pull any fault codes stored in the control. As per the tech sheet the diagnostic cycle is initiated as follows:
RAPID ADVANCE SERVICE FEATURE AND DIAGNOSTICS CYCLES
Pressing the following option keys in the sequence shown will either start the Diagnostics Cycle or turn on the Rapid Advance feature for stepping through customer selectable cycles:
HI TEMP SCRUB, AIR DRY, HI TEMP SCRUB, AIR DRY
Or
SANI RINSE, AIR DRY, SANI RINSE, AIR DRY
(Note: HI TEMP SCRUB = HI TEMP SCOUR)
(Note: AIR DRY = NO HEAT DRY = ENERGY SAVER DRY)
If the above key sequence is entered after starting a cycle, the Rapid Advance feature is turned on, which allows the operator to manually advance the currently running cycle, interval by interval, by pressing the Pots&Pans/Heavy or Anti-Bacteria/Cookware or Start key.
If the above key sequence is entered with the dishwasher in Standby, the Diagnostics Cycle is started. The Diagnostics Cycle can be rapid-advanced, interval by interval, by pressing the Pots&Pans/Heavy or Anti-Bacteria/Cookware or Start key.
Note: The door must be closed before the Diagnostics cycle will run. Likewise, the door must be closed after each rapid advance selection of the P&P/Heavy, A-Bac/Cookware, or Start key for the control to advance to the next interval of the Diagnostics or currently running cycle.
As a note, if the unit will not go into diagnostics, the control and/or the control panel is considered by the manufacturer to be defective.

Read More...

Answered by AppliancePartsPros.com   |   Friday, April 3, 2015

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google