Thing To Fix It for Model Number JS42CSFXDA Jenn Air side by side. Question - When should the damper under the evaporator unit be open and when should it be closed? Had a problem with Ice build up and unit not defrosting. Managed to get everything working and now refrigerator is cool, but freezer is at 29 degrees and the damper is staying open. When I run it through the diagnostic codes - the damper opens and closes properly (so it is working). PS- The damper motor was making a noise, but the door was not opening when I ran the 09 & 10 codes. I removed the damper unit removed some ice build up, and let the unit warm up. Damper opened and closed when reinstalled and I ran the codes.
Answer Thing to fix it, If the damper had ice on it, then this would cause the damper from opening and closing. The temp that the damper should open is when the unit gets warm enough in the refrigerator section which should be around 40 degrees and close when it gets to about 36 degrees. This issue could be caused by a faulty thermistor which is located under the controls. Read More... Answered by AppliancePartsPros.com | Thursday, March 9, 2017