This electronic control module is the appliance's main brain, coordinating cycle timing and sending power to pumps, motors, valves, and heating elements. Replacing a failed board restores reliable operation and resolves erratic or non-start issues.

  • Manages cycle sequencing based on user settings and sensor inputs
  • Distributes power to key components to execute each step of the cycle
  • Common symptoms of failure: won't start, won't advance/complete cycles, or stops mid-cycle
  • Also causes intermittent operation or fault/error codes
Includes: 1 electronic control board Install notes:
  • Disconnect power at the breaker before servicing; use proper ESD precautions
  • Location varies by model
  • Photograph wiring and move connectors one at a time to the new board
  • Secure the board, reassemble panels, restore power, and run a test cycle

More
$294.57
Compare At:
$353.48
You Save:
$58.91

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Electronic Control Board (Central Control Unit) (Part Number: OEM18066783)

View all Questions

Answer

Hello Harlan. If the water temperature sensor (NTC) value is out of range (23°F to 217°F [-5°C to 103°C]) during the water-heating step of the WASH cycle. Possible Causes/Procedure - Unplug washer or disconnect power. - Make sure that connections to water heater & CCU (TH2 & HE2 cavities) connectors are not broken or with wires detached, and that connector internal pins are visible. - Check continuity from the water heater sensor (black wires) to CCU (TH2 cavity) connector. - If the continuity diagnosis failed, the Main Harness must be replaced. - Check the resistance of heating element. - Check the resistance of the water sensor. - Plug in washer or reconnect power. - Verify the washer operation by running the Diagnostic Test cycle. - After the diagnostic test has finished, unplug washer or disconnect power and wait for 15 seconds.

Read More...

Answered by AppliancePartsPros.com   |   Monday, October 6, 2014

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store